M413620
71
3. SELECT FABRIC TYPE –
Press an ON/SELECT pad to select a temperature.
HIGH, MEDIUM, MEDIUM LOW, LOW or NO
HEAT for items that should not be dried with heat. A
light to the left of the selected pad lights up.
Figure 37
ON/SELECT Pads
4. SELECT CYCLE
(AUTOMATIC, TIME DRY OR CUSTOM)
A. Automatic Dry and Condition
When a temperature is selected, “A0:00” will
appear in the display window. Press START to
start the tumbler. “A*:**” will appear in the
display window. The first “*” is the selected
dryness level (dryness levels less than zero will
appear as “-*”), and the “:**” is the elapsed time.
The degree of dryness can be altered. Use the
MORE pad, or the LESS pad, to increase or
decrease dryness level.
NOTE: Dryness level can only be altered prior to the
end of the first heat cycle.
When clothes reach selected dryness level, Cool
Down begins. “AC:**” will appear in the display
window. “:**” is the elapsed Cool Down time.
When Cool Down ends, tumbler automatically
goes into wrinkle-free and “Lr” (Load Ready)
will appear in the display.
AC:** will be displayed when tumbler is in Auto
Cool Down. Typical cool down times for fabric
selections are preset as shown in Table 16. The
cool down time can only be altered before cycle is
started. To alter cool down time press the COOL
DOWN pad and then press the MORE or LESS
pad (when cool down time is altered, TC:** will
be displayed). For 1 minute changes, press pad
and release. For 5 minute changes, press pad and
hold. Cooling time can be from 1 to 39 minutes.
To return to the Auto Cool Down, press MORE or
LESS pad until AC:** is displayed.
Figure 38
DRYNESS Pads
Use the CONDITION pad for items to be left
damp for ironing. “Cn:00” will replace “A0:00” in
the display.
Auto Cool Down ends when either a preset
temperature or a preset time is reached, see Table 16.
Table 16
Automatic Cool Down Temperatures and Times
Fabric
Preset Temp
Preset Time
COTTONS
100° F, 38° C
5 MIN
PERM PRESS
90° F, 32° C
8 MIN
MIXED
90° F, 32° C
5 MIN
DELICATES
90° F, 32° C
5 MIN
Summary of Contents for DT120CSH
Page 2: ......
Page 4: ...2 M413620 Notes...
Page 24: ...22 M413620 Notes...
Page 71: ...M413620 69 Figure 35...
Page 78: ...76 M413620...
Page 80: ...78 M413620...
Page 86: ...84 M413620 Notes...
Page 88: ...86 M413620...
Page 90: ...88 M413620 Notas...
Page 110: ...108 M413620 Notas...
Page 157: ...M413620 155 Figura 35...
Page 164: ...162 M413620...
Page 166: ...164 M413620...
Page 172: ...170 M413620 Notas...