![Alliance Laundry Systems DT120CSH Installation Operation & Maintenance Download Page 123](http://html1.mh-extra.com/html/alliance-laundry-systems/dt120csh/dt120csh_installation-operation-and-maintenance_2901318123.webp)
M413620
121
Para las secadoras de 30, 50 y 75 libras
Tabla 2
TAMAÑO DE LA TUBERÍA DE GAS REQUERIDA PARA 1,000 BTU DE GAS NATURAL - GRAVEDAD
ESPECÍFICA DE 0.64 A UNA PRESIÓN DE COLUMNA DE AGUA DE 6-1/2 ± 1-1/2" (1.62 ± 0.37 kPa)
LONGITUD EQUIVALENTE
TOTAL DE
BTH/h DE
APARATOS DE
GAS
25 PIES
(7.63 m)
50 PIES
(15.25 m)
75 PIES
(22.88 m)
100 PIES
(30.50 m)
125 PIES
(38.13 m)
150 PIES
(45.75 m)
BASADO EN UNA CAIDA DE PRESIÓN DE 0.3" DE LA COLUMNA
DE AGUA PARA LA LONGITUD DADA
100,000
120,000
140,000
160,000
180,000
200,000
300,000
400,000
500,000
600,000
700,000
800,000
900,000
1,000,000
1,100,000
1,200,000
1,300,000
1,400,000
1,500,000
1,600,000
1,700,000
1,800,000
1,900,000
2,000,000
2,200,000
2,400,000
2,600,000
2,800,000
3,000,000
¾" (19.05mm)
¾" (19.05mm)
¾" (19.05mm)
¾" (19.05mm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1¼" (3.18cm)
1¼" (3.18cm)
1½" (3.81cm)
1½" (3.81cm)
1½" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
¾" (19.05mm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1¼" (3.18cm)
1¼" (3.18cm)
1½" (3.81cm)
1½" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1¼" (3.18cm)
1¼" (3.18cm)
1½" (3.81cm)
1½" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3½" (8.89cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1¼" (3.18cm)
1¼" (3.18cm)
1¼" (3.18cm)
1½" (3.81cm)
1½" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3½" (8.89cm)
3½" (8.89cm)
3½" (8.89cm)
1" (2.54cm)
1" (2.54cm)
1" (2.54cm)
1¼" (3.18cm)
1¼" (3.18cm)
1¼" (3.18cm)
1½" (3.81cm)
1½" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3½" (8.89cm)
3½" (8.89cm)
3½" (8.89cm)
3½" (8.89cm)
3½" (8.89cm)
1" (2.54cm)
1" (2.54cm)
1¼" (3.18cm)
1¼" (3.18cm)
1¼" (3.18cm)
1½" (3.81cm)
1½" (3.81cm)
2" (5.08cm)
2" (5.08cm)
2" (5.08cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
2½" (6.35cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3" (7.62cm)
3½" (8.89cm)
3½" (8.89cm)
3½" (8.89cm)
3½" (8.89cm)
3½" (8.89cm)
4" (10.16cm)
PARA GAS L.P., CORREGIR EL TOTAL DE BTU/h MULTIPLICÁNDOLO POR 0.6. LA RESPUESTA SON LAS BTU
EQUIVALENTES EN LA TABLA ANTERIOR.
IMPORTANTE: La instalación tiene que cumplir con los códigos locales, o a falta de códigos locales:
• con la última edición del “National Fuel Gas Code”, ANSI Z223.1, en EE.UU.,
• con CAN1-B149.1 ó CAN1-B149.2, en Canada,
• y los requisitos de la Australian Gas Association / Australian LP Gas Association, en Australia.
Summary of Contents for DT120CSH
Page 2: ......
Page 4: ...2 M413620 Notes...
Page 24: ...22 M413620 Notes...
Page 71: ...M413620 69 Figure 35...
Page 78: ...76 M413620...
Page 80: ...78 M413620...
Page 86: ...84 M413620 Notes...
Page 88: ...86 M413620...
Page 90: ...88 M413620 Notas...
Page 110: ...108 M413620 Notas...
Page 157: ...M413620 155 Figura 35...
Page 164: ...162 M413620...
Page 166: ...164 M413620...
Page 172: ...170 M413620 Notas...