42
M413620
ELECTRICAL REQUIREMENTS
GROUNDING INSTRUCTIONS
This drying tumbler must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. This tumbler must be
connected to a grounded metal, permanent wiring
system; or an equipment grounding conductor must be
run with the circuit conductors and connected to the
appropriate ground location.
NOTE: To ensure protection against shock, this
tumbler MUST be electrically grounded in
accordance with the local codes, or in the absence of
local codes, with the latest edition of the National
Electrical Code ANSI/NFPA No. 70. In Canada the
electrical connections are to be made in accordance
with CSA C22.1 latest edition Canadian Electrical
Code, Part I and/or local codes. Electrical work
should be done by a qualified electrician.
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the tumbler before servicing.
• Close gas shut-off valve to gas tumbler before servicing.
• Close steam gate valve to steam tumbler before servicing.
• Never start the tumbler with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be reconnected
to ensure that the tumbler is properly grounded.
W002
WARNING
To reduce the risk of fire and electric shock, check with a qualified serviceman for proper
grounding procedures. Improper connection of the equipment grounding conductor may
result in a risk of electric shock.
W068
To reduce the risk of fire and electric shock, if electrical supply is coming from a three
phase service, DO NOT connect a “High Leg” or “Stinger Leg” to a single phase machine.
On a three phase machine, if there is a “High Leg” or “Stinger Leg” it should be
connected to L3.
W069
WARNING
All electrical connections should be
made by a qualified electrician.
To reduce the risk of electrical shock, de-
energize the electrical circuit being
connected to the tumbler before making
any electrical connections. Never attempt
to connect a live circuit.
W070
WARNING
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation after
servicing.
W071
CAUTION
Summary of Contents for DT120CSH
Page 2: ......
Page 4: ...2 M413620 Notes...
Page 24: ...22 M413620 Notes...
Page 71: ...M413620 69 Figure 35...
Page 78: ...76 M413620...
Page 80: ...78 M413620...
Page 86: ...84 M413620 Notes...
Page 88: ...86 M413620...
Page 90: ...88 M413620 Notas...
Page 110: ...108 M413620 Notas...
Page 157: ...M413620 155 Figura 35...
Page 164: ...162 M413620...
Page 166: ...164 M413620...
Page 172: ...170 M413620 Notas...