STEAM REQUIREMENTS
For 170 Pound Steam Drying Tumblers Only
Figure 15
Table 6
STEAM
BONNET
12" (30.5 cm)
RISERS
SUPPLY
RETURN
SHUT-OFF
VALVE
TRAP WITH
BUILT-IN
STRAINER
UNION
CHECK
VALVE
CONDENSATE
RETURN LINE
FROM
SUPPLY LINE
VACUUM
BREAKER
SOLENOID VALVE
(Supplied with
machine)
= 3/4" DIAMETER PIPE
= 1" DIAMETER PIPE
T220IE3E
VACUUM
BREAKER
CHECK
VALVE
SHUT-OFF
VALVE
NOTE: Sizing of pipe diameters is shown for
steam at rated pressure of 120 psi. Pipe
diameter needs to be increased accordingly if
pressure is less than 125 psi, see Table 6.
Piping must also be sized accordingly for
length of runs, and number of elbows.
TUMBLER
MODEL
STEAM PRESSURE
(PSI)
MINIMUM PIPE
DIAMETER
STEAM TRAP SIZE
(Pounds Condensate/Hour)
170CSH
110 – 125
1" (2.5 cm)
517
170CSH
60 – 110
1-1/4" (3.2 cm)
517
170CSH
35 – 60
1-1/2" (3.8 cm)
517
Summary of Contents for DT120CSH
Page 2: ......
Page 4: ...2 M413620 Notes...
Page 24: ...22 M413620 Notes...
Page 71: ...M413620 69 Figure 35...
Page 78: ...76 M413620...
Page 80: ...78 M413620...
Page 86: ...84 M413620 Notes...
Page 88: ...86 M413620...
Page 90: ...88 M413620 Notas...
Page 110: ...108 M413620 Notas...
Page 157: ...M413620 155 Figura 35...
Page 164: ...162 M413620...
Page 166: ...164 M413620...
Page 172: ...170 M413620 Notas...