AIR FLOW LIGHT
Only on 120 and 170 Pound Manual Timer Models
The light on the front control panel indicates when the air
flow through the tumbler is less than normal. When this
light flickers on and off or stays on all the time, the
tumbler cannot operate properly. If cleaning the lint
screen does not correct the problem, other possibilities
include: Lint build-up in the exhaust line or discharge
vent, incorrect rotation of blower, lack of make-up air,
jammed back-draft damper, overloaded tumbler or
anything else that will reduce the air flow.
The air flow light is wired to the normally close contact
of the air flow switch, so when the air flow switch flutters
or does not pull in, the light will advise the operator that
there is a problem, which should be corrected
immediately. It is normal for the light to come on for 2
seconds when the tumbler is started. It should go out
when the blower is up to speed.
For 120 lb. Tumblers only.
Figure 25
For 170 lb. Tumblers only.
Figure 26
AIR FLOW
SWITCH
REVERSING
MOTOR
3/4 H.P.
BLOWER
MOTOR
1 H.P.
T173IE1B
FINAL DRIVE
EYE BOLT
DRIVE
MOTOR
EYE BOLT
AIR FLOW
SWITCH
REVERSING
MOTOR
3/4 H.P.
BLOWER
MOTOR
3 H.P.
T283IE1A
FINAL
DRIVE
EYE
BOLT
DRIVE
MOTOR
EYE BOLT
Summary of Contents for DT120CSH
Page 2: ......
Page 4: ...2 M413620 Notes...
Page 24: ...22 M413620 Notes...
Page 71: ...M413620 69 Figure 35...
Page 78: ...76 M413620...
Page 80: ...78 M413620...
Page 86: ...84 M413620 Notes...
Page 88: ...86 M413620...
Page 90: ...88 M413620 Notas...
Page 110: ...108 M413620 Notas...
Page 157: ...M413620 155 Figura 35...
Page 164: ...162 M413620...
Page 166: ...164 M413620...
Page 172: ...170 M413620 Notas...