ELECTRICAL REQUIREMENTS
For 120 Pound Tumblers
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a qualified electrical contractor in accordance with all
applicable local and national requirements.
NOTE: DO NOT use aluminum wire.
* Current Ratings vary slightly depending on model, see serial plate.
Table 13
ELECTRICAL REQUIREMENTS
For 170 Pound Tumblers
NOTE: Minimum wire sizes are obtained from Canadian Electrical Code and are intended for use as a guideline
only. Electrical connections should be made only by a qualified electrical contractor in accordance with all
applicable local and national requirements.
NOTE: DO NOT use aluminum wire.
* Current Ratings vary slightly depending on model, see serial plate.
Table 14
Heat Source
Serial Plate Voltage
Terminal Block
Connections Required
Rated
Current
Breaker
Rating
Breaker
Poles
Recommended
Wire Size
Gas & Steam
208-230V/60Hz/3ph
L1, L2, L3, and ground
*
10 Amps
3
14 AWG
Gas & Steam
380-415V/50Hz/3ph
L1, L2, L3, and ground
*
10 Amps
3
14 AWG
Gas & Steam
460-480V/60Hz/3ph
L1, L2, L3, and ground
*
10 Amps
3
14 AWG
Heat Source
Serial Plate Voltage
Terminal Block
Connections Required
Rated
Current
Breaker
Rating
Breaker
Poles
Recommended
Wire Size
Gas & Steam
208-230V/60Hz/3ph
L1, L2, L3, and ground
*
30 Amps
3
10 AWG
Gas & Steam
380-415V/50Hz/3ph
L1, L2, L3, and ground
*
20 Amps
3
12 AWG
Gas & Steam
460-480V/60Hz/3ph
L1, L2, L3, and ground
*
15 Amps
3
14 AWG
Summary of Contents for DT120CSH
Page 2: ......
Page 4: ...2 M413620 Notes...
Page 24: ...22 M413620 Notes...
Page 71: ...M413620 69 Figure 35...
Page 78: ...76 M413620...
Page 80: ...78 M413620...
Page 86: ...84 M413620 Notes...
Page 88: ...86 M413620...
Page 90: ...88 M413620 Notas...
Page 110: ...108 M413620 Notas...
Page 157: ...M413620 155 Figura 35...
Page 164: ...162 M413620...
Page 166: ...164 M413620...
Page 172: ...170 M413620 Notas...