16
513447
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Dryer Troubleshooting
6. Dryer Heating Assembly Does Not Heat or Burner Does Not Ignite
Dryer heating assembly does not
heat or burner does not ignite.
Is exhaust
system
improper or
inadequate?
Refer to
Installation
Instructions
(supplied with
unit) for
exhaust
requirements.
Is exhaust
duct made of
plastic or thin
foil?
No
Replace with
rigid or semi-
rigid metal
exhaust duct.
Yes
Is house fuse
blown or
circuit breaker
tripped?
Check fuses or
circuit breakers. A
240 Volt electric
heat dryer uses two
fuses. Make sure
both fuses are
good.
Yes
Electric
Models: Is
heater assembly
inoperative?
Test heater
assembly and
replace if cold
Ohms do not
read between
9 and 10.5
Ohms.
Yes
Electric
Models: Is
thermal fuse
inoperative?
Test thermal
fuse and
replace if
inoperative.
Refer to
Test
Procedures
section.
Yes
DRY1848Sa
Yes
No
Continued on
next page.
No
Is limit
thermostat
inoperative?
Test thermostat
and replace if
inoperative.
Refer to
Test
Procedures
section.
Is drive
motor switch
inoperative?
Test switch
and replace if
inoperative.
Is termperature
selector switch
set at FLUFF/NO
HEAT or
inoperative?
No
No
Reset or test
switch and
replace if
inoperative.
Yes
No
Yes
No
Yes
No