513447
51
Adjustments
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
i. Check coin return pendulum to verify it swings
freely. If pendulum does not swing freely, spray
pendulum pivot point with Teflon based
lubricant and move pendulum back and forth
two to three times. An additional application of
Teflon based lubricant may be necessary to
ensure that pendulum swings freely. Refer to
Figure 15
.
j. Check coin drop sensor for dust or dirt on eyes.
Wipe eyes with dry cotton swab. Refer to
Figure 16
.
IMPORTANT: DO NOT use isopropyl alcohol to
clean electronic sensor or eyes.
k. Reinstall coin return on to coin drop frame.
l. Reinstall metal clip and slide towards coin
insert slot. All cotter pin holes must line up.
m. Reinstall cotter pin.
n. Place drop on level surface to verify that coins
follow correct path in drop. It may be necessary
to lift drop to allow coin to follow through
sensor.
o. Reinstall coin drop into machine.
p. Reconnect electrical power to machine and
drop.
q. Add a coin to drop to verify that coin drop is
operating properly and that electrical
connection is working properly.
NOTE: If coin drop does not operate properly after
above steps have been completed, corrosion of
metal or vandalized components within coin drop
may be preventing the coin drop from functioning
correctly. Replace coin drop.
Figure 15
DRY6B
Pivot
Point
Pendulum
Figure 16
DRY7B
Eyes
Dry
Cotton
Swab
Summary of Contents for BD3LLFGS401UW01