513447
61
Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
34. Motor Switch
a. Remove motor and exhaust fan assembly.
b. Remove the two motor switch attaching screws.
Refer to
Figure 32
. Disconnect switch leads.
Remove motor switch.
c. Remove thermal overload protector.
NOTE: The thermal overload protector is unique
to the motor from which it was removed and should
only be used on that motor. To reduce the risk of
overheating the motor, do not use any thermal
overload protector other than the one taken from
the inoperative motor switch in step 3.
(1)
Motor with Switch on Blower End
Using a small bladed screwdriver, press the
thermal overload protector mounting tab
downward and remove the thermal
overload protector from the inoperative
motor switch. Refer to
Figure 28
.
Figure 28
D02
9
KE3A
Mounting
Tab
Thermal
Overload
Protector
Motor
Switch
Summary of Contents for BD3LLFGS401UW01