Test Procedures
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
To reduce the risk of electric shock, fire, explosion, serious injury or death:
• Disconnect electric power to the dryer(s) before servicing.
• Close gas shut-off valve to gas dryer(s) before servicing.
• Never start the dryer(s) with any guards/panels removed.
• Whenever ground wires are removed during servicing, these ground wires must be
reconnected to ensure that the dryer is properly grounded.
W001R1
WARNING
38. Sensor Check (Gas Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel.
c. Close main gas shut-off valve. Refer to
Figure 11
.
d. Remove wires from sensor terminals.
e. Set test meter to read Ohms and put meter
probes on sensor terminals. Meter should read
“zero” Ohms. If meter registers an Ohm reading
of any amount, replace sensor.
39. Igniter Check (Gas Models)
a. While supporting the access panel, remove two
screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel.
c. Close main gas shut-off valve. Refer to
Figure 11
.
d. Disconnect igniter wires at disconnect block.
e. Set test meter to read Ohms and put meter
probes on terminals of igniter wires.
f.
Silicon Carbide Igniter
: Meter should read
between 45 – 200 Ohms.
Silicon Nitride Igniter
:
Meter should read
between 49 – 88 Ohms.
NOTE: If meter does not read appropriate Ohms,
then replace the igniter.
IMPORTANT: Always examine all wires, terminals
and connectors to be sure wiring is correct before
replacing any components.
40. Ignition Control Grounding
Check (Silicon Nitride Ignition)
a. While supporting the access panel, remove two
screws from bottom edge of access panel.
b. Gently lower the access panel to disengage
locators from bottom edge of front panel.
c. Close main gas shut-off valve. Refer to
Figure 11
.
d. Remove wires from sensor terminals.
e. Set test meter to read Ohms and put meter
probes on the ground wire connection in 12-pin
block (connected to module) and on the green
ground screw in base of dryer.
f. Meter should read “zero” Ohms. If meter
registers an Ohm reading of any amount, check
ground wire connection and replace as
necessary.
41. Thermal Fuse (Electric Models)
a. While supporting the access panel, remove two
screws from bottom edge of front access panel.
b. Gently lower the access panel to disengage
panel locators from bottom edge of front panel.
c. Label and disconnect wires from thermal fuse.
NOTE: Refer to wiring diagram when rewiring
thermal fuse.
d. Set multimeter to read Ohms. Apply meter
probes to thermal fuse terminals. Multimeter
should read 0 Ohms. If the meter does not show
any reading (infinite Ohms), then the fuse is
open. If the fuse is open, then replace BOTH
the thermal fuse and the limit thermostat.