1
Publication 1734-UM003A-EN-P - August 2000
Chapter
3
Very High Speed Counter Module Input and
Output Data
In This Chapter
In this chapter, you will learn about the input/output data table of
your 1734-VHSC24 and -VHSC5.
Data Table
The following table shows the complete format of the input/output
data.
For more information about:
See page:
Detailed Description of Data Table Information
Communicating Real Time/Non-real Time Information
15
14
13
12
11
10
09
08
07
06
05
04
03
02
01
0
Input Information
Present Channel Data
32-bit Value of the present counter state
Stored Channel Data
32-bit value of the stored/accumulated count
Status
PE
EF
NR
0
FS
FS
OS
OS
0
ZS
BS
AS
C1
C0
ZD
0
Programming Error Code
PE
0
0
0
0
E10
E9
E8
E7
E6
E5
E4
E3
E2
E1
E0
Output Information
Counter Control
0
0
0
0
0
VR
CP
CR
Output Control
DS
ES
OE
FO
DS
ES
OE
FO
PWM Value
16-bit decimal value with range from 0-9500 (0-95.00%)
Configuration Information
Counter Configuration
ZI
MD
MD
MD
CF
CF
CF
CF
Filter Selection
0
ZF
BF
AF
FS
FS
FS
FS
Decimal Position
8-bit value used to modify the present channel data display
Active Output Assembly
Assembly number (0, 105 or 106)
Time Base/PWM Period
16-bit value used to set the time base or PWM period
Gate Interval
8-bit value used to set the gate interval
Summary of Contents for POINT I/O 1734-VHSC24
Page 1: ...Very High Speed Counter Module Cat No 1734 VHSC5 and VHSC24 User Manual ...
Page 22: ...Publication 1734 UM003A EN P August 2000 1 14 About the Very High Speed Counter Modules ...
Page 48: ...Publication 1734 UM003A EN P August 2000 4 8 Configuring Your Very High Speed Counter Module ...
Page 63: ......