Publication 1734-UM003A-EN-P - August 2000
About the Very High Speed Counter Modules
1-13
Effect of ON-OFF Value on Output Operation
Chapter Summary
In this chapter, you learned about the kinds of very high speed
counter modules, and what modes they operate in. Read chapter 2 to
install your counter module.
Effect of ON-OFF Value on Output Operation
Output turns ON
Output turns OFF
Output remains Energized
at count of 2000
for 3000 additional counts
at count of 5000
Turn Off Value > Turn On Value
Output turns OFF
Output turns ON
Output remains Deenergized
at count of 2000
for 3000 additional counts
at count of 5000
Turn On Value > Turn Off Value