28
Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Chapter 1
Product Overview
Figure 7 - Control Circuit Wiring Diagram — Multiple External Power Supplies
Figure 8 - Control Circuit Wiring Diagram — Internal Power Supply (optional)
Outputs
Inputs
EtherNet
Comms
A3
A1
A2
Off
Switched Control Power
Unswitched Control Power
Motor
Control
Motor
Controller
Class 2
External Switched
24VDC Power Supply
Disconnect
24VDC
+
-
L
N
L1
L2
L3
24VDC
+
-
L
N
Class 2
External Unswitched
24VDC Power Supply
* Control power output is determined by disconnect status
*
T1
T2
T3
ArmorStart
LT
Outputs
Inputs
EtherNet
Comms
Off
Motor
Control
Motor
Controller
Disconnect
Internal Power
Supply
*
* Control power output is determined by disconnect status
T1
T2
T3
ArmorStart
LT
*
L2
L3
L1
Summary of Contents for ArmorStart 290E
Page 1: ...ArmorStart LT Distributed Motor Controller Catalog Numbers 290E 291E 294E User Manual ...
Page 8: ...8 RockwellAutomationPublication290E UM001B EN P June2012 Summary of Changes Notes ...
Page 228: ...228 RockwellAutomationPublication290E UM001B EN P June2012 Appendix B CIP Information Notes ...
Page 251: ......