Chapter 4
Bulletin 290E/291E/294E Programmable Parameters
OutNetIdleValue
This parameter determines the state that
starter outputs assumes when the
network is idle and Parameter 56
(OutNetIdleState) is set to 0.
0 = OFF
1 = ON
Parameter Number
57
Access Rule
GET
Data Type
BOOL
Group
User I/O Config.
Units
—
Minimum Value
0
Maximum Value
1
Default Value
0
Input00Function
This parameter determines the special
function for User Input 0:
0 = NoFunction
1 = FaultReset
2 = MotionDisable
➊
3 = ForceSnapShot
4 = UserFault
5 = BrakeRelease
➊
➊
These choices are level sensitive. All
others are edge sensitive
Parameter Number
58
Access Rule
GET/SET
Data Type
USINT
Group
User I/O Config.
Units
—
Minimum Value
0
Maximum Value
4
Default Value
0
Input01Function
This parameter determines the special
function for User Input 1:
0 = NoFunction
1 = FaultReset
2 = MotionDisable
➊
3 = ForceSnapShot
4 = UserFault
5 = BrakeRelease
➊
➊
These choices are level sensitive. All
others are edge sensitive
Parameter Number
59
Access Rule
GET/SET
Data Type
USINT
Group
User I/O Config.
Units
—
Minimum Value
0
Maximum Value
4
Default Value
0
Input02Function
This parameter determines the special
function for User Input 2:
0 = NoFunction
1 = FaultReset
2 = MotionDisable
➊
3 = ForceSnapShot
4 = UserFault
5 = BrakeRelease
➊
➊
These choices are level sensitive. All
others are edge sensitive
Parameter Number
60
Access Rule
GET/SET
Data Type
USINT
Group
User I/O Config.
Units
—
Minimum Value
0
Maximum Value
4
Default Value
0