Connect the Kinetix 7000 Drive System
Chapter 4
Wire AC Input Power
Wire 460V AC input power to your Kinetix 7000 drive as described in
See Power Terminal Block (PTB) Connections for more information.
Table 35 - AC Input Power Connections
Wire DC Input Power (Common Bus Configurations Only)
Wire the DC input power from a leader regenerative power supply (8720MC-
RPS) to a Kinetix 7000 drive as described in
(PTB) Connections on page
for more information.
Kinetix 7000
Drive Cat. No.
Signal
Terminal
Recommended Wire Size
mm
2
(AWG)
Torque
N
•
m (lb
•
in)
2099-BM06-S
2099-BM07-S
2099-BM08-S
L1
L2
L3
Ground
R
S
T
PE
25…2.5 (3…14)
1.8 (16)
2099-BM09-S
L1
L2
L3
R
S
T
50…4 (1/0…12)
3.6 (32)
Ground
PE
50…4 (1/0…12)
5 (44)
2099-BM10-S
L1
L2
L3
R
S
T
70…10 (2/0…8)
15 (133)
Ground
PE
50…4 (1/0…12)
5 (44)
2099-BM11-S
2099-BM12-S
L1
L2
L3
R
S
T
100…10 (4/0…8)
12 (104)
Ground
PE
50…4 (1/0…12)
5 (44)
IMPORTANT
DC power from the regenerative power supply (8720MC-RPS) is typically
routed to a power distribution box. Fusing will be placed before and after
the distribution box, providing protection for both the 8720MC-RPS and
Kinetix 7000 drive.