39.
From the Bus Regulator Configuration pull-down menu, choose the
component appropriate for your actual hardware configuration. Note: The
Kinetix 7000 drive internal dynamic brake IGBT is not utilized by the
drive main control for bus regulation therefore any type of regulation must
come from an external source.
40.
Click OK.
41.
Repeat steps 1…27 for each additional axis.
42.
Verify your Logix program and save the file.
Download the Program
After completing the Logix configuration you must download your program to
the Logix processor.
If your drive requires
Then choose
No bus regulator configuration
<none>
External Shunt configuration
1336-MOD-KB005, KB010 or KB050
1336-WB009, WB035 or WB110
(1)
(1) External shunt configuration 1336 MOD-KB
xxx
and 1336-WB
xxx
are no longer available for new sale but are selectable as
of this manual release.
External regeneration power supply
8720MC-RPS027, 8720MC-RPS065, or 8720MC-RPS190
(2)(3)(4)
(2) 8720MC-RPS
xxx
is an external regenerative converter system used to regulate the DC bus connected to the Kinetix 7000
drive. Selecting this device will require the Kinetix 7000 drive GPIO terminal block pins 7 and 8 to be wired. See
for an example.
(3) 8720MC-RPS027BM-HV1 is no longer available for sale.