![Allen-Bradley 2099-BM06-S User Manual Download Page 53](http://html1.mh-extra.com/html/allen-bradley/2099-bm06-s/2099-bm06-s_user-manual_2900680053.webp)
Rockwell Automation Publication 2099-UM001D-EN-P - December 2012
53
Kinetix 7000 Connector Data
Chapter 3
Figure 30 - 2099-BM11-S and 2099-BM12-S
Table 18 - Power Terminal Block
Terminal
Description
Name
DC+
DC Bus Power
DC Bus (+)
DC-
DC Bus (-)
PE
Main Ground of the Drive System
PE Ground
GND
Motor Ground
Motor Ground
U-T1
Motor Phase U Output
U (T1)
V-T2
Motor Phase V Output
V (T2)
W-T3
Motor Phase W Output
W (T3)
R-L1
Main 380…480V AC +/-10% Input Power, Three-phase to R, S and T Input Terminals
R
S-L2
S
T-L3
T
120VAC
+120V AC Input for Fan Power
VAC_FAN_1
240VAC
+240V AC Input for Fan Power
VAC_FAN_2
0VAC
Fan Common
GND_FAN
PS-
For factory use only
–
PS+
For factory use only
–
FAN
PS+
PS-
Motor
AC Line
Fan Terminals
Enlarged View
0 V
AC
120 V
AC
240 V
AC