Rockwell Automation Publication 1756-UM001O-EN-P - October 2014
Chapter 3
Start Using the Controller
If the auto configuration is not successful, verify that the correct Comm
Port was selected.
7.
Click Close.
Upgrade Controller Firmware
You can choose to upgrade controller firmware by using one of these tools:
•
ControlFLASH™ software that is packaged with the Studio 5000
environment
•
AutoFlash feature of the Logix Designer application
To upgrade your controller firmware, complete the tasks that are listed in this
table.
Determine Required Controller Firmware
Use
to determine what firmware revision is required for your controller.
Task
Page
Determine Required Controller Firmware
Use ControlFLASH Software to Upgrade Firmware
Use AutoFlash to Upgrade Firmware
IMPORTANT
The controller must be in Remote Program or Program mode and all major
recoverable faults must be cleared to accept upgrades.
Table 4 - Firmware Required for Controllers
Controller
Series
Use this firmware revision
1756-L61
A
12
.x
or later
B
13.40 or later
1756-L62
A
12
.x
or later
B
13.40 or later
1756-L63 A
•
If not using a CompactFlash card, 10
.x
or later
•
If using a CompactFlash card, 11
.x
or later
B
13.40 or later
1756-L63XT
B
13.40 or later
1756-L64
B
16 or later
1756-L65
B
17 or later
1756-L71
A
20 or later
1756-L72
A
19 or later
1756-L73
A
19 or later
1756-L73XT
A
19 or later
1756-L74
A
19 or later
Summary of Contents for 1756-L63XT
Page 4: ...4 Rockwell Automation Publication 1756 UM001O EN P October 2014 Summary of Changes Notes...
Page 18: ...18 Rockwell Automation Publication 1756 UM001O EN P October 2014 Preface Notes...
Page 136: ...136 Rockwell Automation Publication 1756 UM001O EN P October 2014 Chapter 8 I O Modules...
Page 210: ...210 Rockwell Automation Publication 1756 UM001O EN P October 2014 Index Notes...
Page 211: ......