Publication 1404-UM001D-EN-E - October 2004
Powermonitor 3000 Operations
3-3
Metering Accuracy Class
Table A.16, element 26 is a read-only parameter that indicates the
revenue metering accuracy class of the Master Module. If this element
contains the value 0, the Master Module meets ANSI C12.16 and
EN61036 Class 1 requirements for accuracy. If this element contains
the value 1, the Master Module meets ANSI C12.20 Class 0.5, EN60687
Class 0.5, and Canadian standard CAN3-C17-M84 requirements for
accuracy. If this element contains the value 2, the Master Module
meets ANSI C12.20 Class 0.2, EN60687 Class 0.2, and Canadian
standard CAN3-C17-M84 requirements for accuracy. The revenue
metering accuracy class is also indicated on the side of the Master
Module and can be accessed via the Display Module
(
DISPLAY
>
STATUS
>
ACCURACY
CLASS
).
Expressing Metered Data on the Display Module
The Display Module displays scaled metered data in its basic units,
such as volts, amps, watts, etc. Prefixes such as “K” or “M” are used to
denote multipliers of 1,000 (kilo-) and 1,000,000 (mega-). The DM
expresses Power factor as a percentage, with a positive value
indicating leading and a negative value indicating lagging.
The Display Module displays values to a maximum precision of five
significant digits.
Viewing Metered Data Using the Display Module
The Display Module makes it easy to view the metering data
produced by the Powermonitor 3000. Refer to Display Module
Functionality later in this chapter for information on use of the Display
Module.
Table 3.2 Metering Accuracy Class
Model
Class 1
Class 0.5
Class 0.2
M4
Standard
Not Available
Not Available
M5
Standard
Optional
M6
Standard
Optional
M8
Standard
Optional
Summary of Contents for 1404-M4
Page 6: ...Publication 1404 UM001D EN E October 2004 Table of Contents 4 ...
Page 26: ...Publication 1404 UM001D EN E October 2004 2 14 Product Description ...
Page 264: ...Publication 1404 UM001D EN E October 2004 C 10 Sample Applications ...
Page 278: ...Publication 1404 UM001D EN E October 2004 C 24 Sample Applications ...
Page 279: ...Publication 1404 UM001D EN E October 2004 Sample Applications C 25 Allen Bradley HMIs ...
Page 280: ...Publication 1404 UM001D EN E October 2004 C 26 Sample Applications ...
Page 285: ...Publication 1404 UM001D EN E October 2004 Sample Applications C 31 Allen Bradley HMIs ...
Page 304: ...Publication 1404 UM001D EN E October 2004 D 6 Technical Specifications ...
Page 324: ...Publication 1404 UM001D EN E October 2004 F 18 Powermonitor 3000 EtherNet IP Device Profile ...
Page 340: ...Publication 1404 UM001D EN E October 2004 G 16 Powermonitor 3000 ControlNet Device Profile ...
Page 354: ...Publication 1404 UM001D EN E October 2004 6 Index ...
Page 355: ...Allen Bradley HMIs ...