Manual
SmartHandle AX
20 / 55
SimonsVoss
4 | Installation
Fig. 6:
Programming passive (SmartCD.MP)
ü
Locking device added in LSM software.
ü
LSM software launched.
ü
Programming device connected.
1. Position the programming device.
2. Programme the SmartHandle AX (see , quick guide or LSM manual for
details).
ð
SmartHandle AX is programmed.
Trim screws
Screw/spindle
Length
2× L1
T - 8 mm (± 3 mm)
2× L2
T + 8 mm (± 3 mm)
Spindle
T + 37 mm (± 4 mm)
1. Measure the thickness of the door (T).
2. Calculate the screw lengths.
3. Select suitable predetermined breaking points which are no more than
3 mm longer than the calculated length.
4. Separate the predetermined breaking points with the pliers.
ð
Screws are trimmed.
IMPORTANT
X variant
If you have ordered the X version for very thick doors, your supply package
will include an extra-long spindle bar and threaded rods in addition to ex-
tension sleeves. The indicated length in this case refers to the extension
with a threaded rod. Use a saw to trim the screws and spindle bar.
Prepare inside
handle (DIN R)
Installation is different for each opening side (DIN R or DIN L).