Manual
SmartHandle AX
28 / 55
SimonsVoss
5 | Programming
5 Programming
ü
LSM software version 3.4 SP1 or higher installed.
ü
LSM open.
ü
SmartCD.MP or SmartCD.G2 connected (recommended:
SmartCD.MP).
1. Select the locking system that you require. Use the ... button to open
the locking system properties and use the and buttons to select the
required lock system.
2. Click on the button to add a new locking device.
ð
The "New lock" window will open.
3. Open the Area drop-down menu.
4. Select the area.
5. Open the Lock type drop-down menu.
6. Select the "AX SmartHandle" item.
7. Complete the rest of the form.
8. Click on the Save & next button.
ð
Locking device has been added.
9. Click on the Exit button.
ð
Window closes.
10. Highlight the entry on the SmartHandle AX in the matrix.
11. Align the Smart CD.MP with the SmartHandle AX or place the
SmartCD.G2 about ten centimetres away from the SmartHandle.AX.
IMPORTANT
A large volume of data is transmitted during initial programming. You can
transfer data significantly faster and reduce the programming time if you
use a Smart CD.MP.
12. Right-click on the SmartHandle AX entry in the matrix to open the
context menu.
13. Select the Programming item.
14. Open the Type drop-down menu.
15. Select the "SmartCD Mifare" entry or "SmartCD aktiv" entry.
16. Click on the Programming button.
ð
Programming launches.