- 15 -
INSTALLATION
Clean the surface with a damp cloth,
do NOT use chemical solvents
CISA MYEVO KEYPAD/RFID 06525.71/73/75
To carry out this installation, the panel must be at least 5 mm thick.
1. Make a hole in the panel, respecting the tolerances shown in the drawing.
2. Place the bracket (5A) in the hole in the direction indicated
and Top-Alto on it, making
surethefourflapsadheretothepanel.Screwinthedowel(G)untilthebracketis
secured into place. An adhesive may be used to ensure the bracket is completely secure
and should be applied as shown( ). CISA recommends Loctite
®
flexibleadhesive.
3. Connect the keypad cable (C4) to the keypad (5B).
4. Insert the keypad (5B) into the bracket (5A) and secure it into position by pulling it
downwards.
The RFID reader will not work if placed in direct contact with a metal
panel. The antenna of the RFID reader must be at least 5 mm and no more
than 20 mm from the metal surface placed behind the door panel.
5B
G
C4
5A
67
69.6
R5
0,2
0,2
06525.71.73