INSTALLATION
SAFETY REGULATIONS
• The electric system must comply with regulations in force.
• Always disconnect the electric system from the mains when connecting the cables or
performing any later work on the lock.
• Do not power the lock directly from the mains but use a power supply recommended by
the manufacturer.
• Protect the system appropriately against short circuits.
• Use the cables supplied with the lock and its accessories only.
CISA declines all responsibility for damage resulting from the failure to observe the above
warnings or when accessories are not used as described in this manual.
KEY:
1. MyEVO motorised lock
2. Pair of Door Status contacts
3. Battery holder
4. Button group
5. Keypad/RFID group
6. Power supply: INPUT V: 180-264 V; 50-60 Hz; 0.7 A - OUTPUT V: 24 V ; 1.3 A
Connect the power supply to the lock with a cable with a max. length of 3 m
The 24V power supply must be protected with a 1.6A fuse 250V type F1.6 A
CE marked, in compliance with Directives 2014/30/EU, 2014/35/EU
Class 2 (double isolation)
LPS source (in compliance with IEC 60950)
OVP (for overvoltages) and OCP (for overcurrents) protection
SELV
UL94-V0 plastic
Product UL Listed or at least UL Recognized
7. Cable guard