1.
Prepare door for exit device. See exit
device instructions for locations of
holes, backset (line X-X), and center
lines.
2.
Prepare door for control:
A.
Transfer line X-X from inside (exit
device side) of door to outside
(control side) of door. Use extra
care if edge of door is beveled.
Be sure line X-X is parallel to edge
of door.
B.
Locate and prepare holes as
indicated.
3.
Install cylinder if required (Figs. 1 &2).
Insure cylinder cam is set for required
function and replace if necessary.
4.
Install control and rub plate (Fig. 2)
5.
Slip rod member on top rod.
6.
Install top rods (see direction for
vertical rod device).
7.
Position rod member so finger contacts
cam when top latch bolt is extended.
8.
Tighten set screws in rod member.
9.
Apply device and test key, control,
and device action.
1-3/8” dia.
(BE only)
Omit cylinder
for BE function
For cutouts on inside face
of door see instructions in
device carton