1

• 

  This product is designed for household use only. Use in a commercial application will void your valuable warranty.

•   NEVER attempt to repair or service your ionpia H

2

 yourself. Attempting to do so will void your valuable warranty.    

    Contact AlkaViva Technical Support to arrange service or repair.

•   If your ionpia H

2

 becomes submerged in water, unplug the power cord from the wall before removing. Failure to do so  

          

    could result in shock!

•   Filters should be replaced per manufacturer suggestion at the end of the filter life. It is important that the 

    replacement filters are installed in the correct position with every filter change.

•   The ionpia H

2

 must be grounded! In the event of malfunction or breakdown the grounding conductor will prevent risk of    

    electric shock/spark. The electrical plug must be plugged into an appropriate outlet that is installed and grounded in 

    compliance with all local codes and ordinances. 

•   When installing your ionpia H

2

 use only manufacturer provided parts and equipment. Using third-party or after-market  

                

    parts can void your valuable warranty.

•   Always install on a solid and level surface. Do not move your ionpia H

2

 while in use.

•   DO NOT install or use your ionpia H

2

 near open heat sources or open flames such as stoves, ranges, heater vents or  

       

    candles.

•   The ionpia H

2

 can be used on 110v~240v. Always be sure to use the appropriate factory electrical plug. Always make  

     

    sure that the plug is firmly inserted into the outlet. Never try to make any modifications to manufacturers original   

    equipment, and never use a damaged power cord. 

•   Be sure that the power adapter is placed where it will not come into contact with water.  

•   Protect your ionpia H

2

 from freezing temperatures and direct sunlight.

•   Only operate your ionpia H

2

 with cold water. Hot water will damage your filters.

•   If The ionpia H

2

 makes strange or unusual noises or odors, unplug the power cord immediately and contact AlkaViva Technical  

    Support.

•   Unplug The ionpia H

2

 if you plan on not using it for an extended period (2 weeks). Store your filters in a plastic bag in  

      

     the refrigerator to prevent bacterial growth. In cases of extended periods of non-use (4+ weeks), filter replacements may         

     be necessary.

•   Do not use your ionpia H

2

 with well water, water with extreme hardness, high sediment or TDS without first contacting  

     

    AlkaViva Technical Support.

•   Your ionpia H

2

 is not under warranty for any damages caused by hard water or environmental conditions.

•   Only clean the exterior with warm water, detergent and a soft rag or paper towel. Do not use chemical or abrasive  

 

     cleaners – they can damage the surface. Do not spray or pour water over your ionpia H

2

. Never submerge your 

     ionpia H

2

•   Do not close, bend, pinch, press or otherwise obstruct inlet supply lines, or equipment.   

Safety, Installation and Operating Precautions

Precautions and Safeguards

Summary of Contents for The ionpia H2

Page 1: ...from AlkaViva Hydrogen Enhanced Living The ionpia H2 Owner s Manual Warning Incorrect installation and or operation could void your valuable warranty Please protect your investment READ THIS MANUAL CAREFULLY ...

Page 2: ...HYDROGEN GENERATOR H2 Page 2 TABLE OF CONTENTS Safety Precautions Quick Tour of the ionpia H2 Installation Operation Replacing your Filters Product Specifications 03 04 06 10 10 12 ...

Page 3: ... can be used on 110v 240v Always be sure to use the appropriate factory electrical plug Always make sure that the plug is firmly inserted into the outlet Never try to make any modifications to manufacturers original equipment and never use a damaged power cord Be sure that the power adapter is placed where it will not come into contact with water Protect your ionpia H2 from freezing temperatures a...

Page 4: ...age 4 2 Water Dispensing Knob Water Outlet Water Trap Grill Filter Cover Faucet Port for Filtered Water Only No H2 Production Water Source Inlet for H2 Production Quick Tour of The ionpia H2 Back of The ionpia H2 Power Inlet ...

Page 5: ...HYDROGEN GENERATOR H2 Page 5 Overview of The ionpia H2 LED Light Carbon Filter Overflow Tray Water Outlet Flow Control Knob UF Membrane Filter Post Carbon Filter ...

Page 6: ...umbed directly to your cold water line no diverter It is recommended that Method 2 be completed by a licensed plumber Installation Options Make Sure You Have All the Accessories 1 2 3 4 1 Faucet Diverter 2 1 4 White Tubing 3 Adapter and power cord for power connection AC 100 240V DC 12V 5A 4 Instruction Manual 5 Angle Stop Adaptor 6 DigiFlow Meter Before installation please check to ensure you hav...

Page 7: ...the tubing connector Be sure to push it onto the connector as far as it will go This may require a firm push Failure to seat it all the way may cause a leak 6 Slide the compression nut back over the supply line to the diverter valve and thread into place Ensure the nut is screwed firmly in place but do not overtighten Part 1 Part 2 1 Connect the white 1 4 tubing into the Water Source Inlet on the ...

Page 8: ... tubing simply push it firmly into the Water Source Inlet port Give it a gentle tug to ensure proper connection It should not come out To remove tubing press the collet towards the fitting and pull the tubing out at the same time NOTE Use of faucet port is NOT recommended as it will NOT produce Hydrogen rich water only filtered water 4 POSITION YOUR ionpia H2 Ensure it is on a hard and level surfa...

Page 9: ...nd show remaining filter life capacity It will automatically shut off 10 seconds after the water flow stops When no water is being ran through it you can view the remaining filter life by pressing CHECK RESET button The DigiFlow meter counts down meaning it will show you how many gallons are left not how many have been used When the meter reaches zero 0 indicating your filters have expired the Dig...

Page 10: ...flow of water and remove any residual water inside your ionpia H2 3 Open Filter Cover Note If your ionpia H2 is connected directly to your cold water line skip step 1 and start at step 2 1 Turn your tap water onto cold then turn the lever on your diverter valve This will divert the water from the tap to The ionpia H2 At this point check all connections for leaks tighten or re seat if needed If the...

Page 11: ...dle by aligning the grooves Press it in and turn clockwise a quarter turn to lock it into place See Figure 2 6 After installing your new filters close the Filter Cover 7 Turn on source water to the ionpia using either the diverter or the Cold Water Supply 8 It is important to flush the filters before you start drinking the water Do this by running water through the unit for several minutes or unti...

Page 12: ...Water Pressure Allowance Water Temperature External Dimension Weight Filter Rating The ionpia H2 Neutral Water Hydrogen Generator 100 240V DC12V 50 60Hz 65W Mechanical Household drinking water 29 psi 58 psi 40 F 80 F DO NOT USE HOT WATER 5 W x 17 5 D x 13 5 H 9 75 lbs Rated at 700 gallons or 1 year whichever comes first 5 17 5 13 5 6 ...

Page 13: ...Hydrogen Enhanced Living Revision Version Date 7 24 2017 Dealer Information ...