Install Method 2:  Direct connect to your water supply

1.  Install Angle Stop Adapter (included) to COLD WATER SUPPLY LINE. Locate the cold water line. 

Shut off the cold water supply. Unscrew the flexible supply line from the angle stop. Attach the 

adapter. (Fits standard 1/2” and 3/8” plumbing.) 

2.  ATTACH THE WHITE 1/4” TUBING TO THE ANGLE STOP ADAPTER

(Fig. 1) Attach the white 1/4” tubing to the adapter by simply pushing firmly into the white port. 

Give a gentle tug to ensure proper connection. It should not come out. You will need a way to 

route the white tubing from the adapter to your ionpia H2. Most newer sinks have cutouts that 

will work for this. If not, drill a 1/4” hole.
3.  ATTACH THE WHITE 1/4”  TUBING TO YOUR ionpia H

2

. (Fig. 2) Attach opposite end (free end) of 

the 1/4” tubing to the white Water Source Inlet port on the back of the ionpia H

2

. To attach the 

white tubing, simply push it firmly into the Water Source Inlet port. Give it a gentle tug to ensure 

proper connection. It should not come out.  To remove tubing, press the collet towards the fitting 

and pull the tubing out at the same time.

NOTE: 

Use of faucet port is NOT recommended as it will NOT produce Hydrogen-rich water, 

only filtered water.

4.  POSITION YOUR ionpia H

2

 - Ensure it is on a hard and level surface. See installation precautions.

5.  CONNECT THE POWER CORD - Use an appropriate grounded outlet.

6. TURN THE COLD WATER SUPPLY ON. Open the valve on the Angle Stop Adapter. The valve is 

open when the blue handle on the Angle Stop Adapter is parallel with the 1/4” white tubing. 

Check all connections for leaks.

Fig. 1 

Angle Stop Adaptor

Fig. 2 

Tap Water Inlet Connection

https://vimeo.com/144697017

Watch video for how to direct plumb The ionpia H

2

1/4” tubing 

going to 

The ionpia H2

Cold Water 

Shut Off Valve

Angel Stop

Valve

To Existing 

Faucet

Connect 1/4” tubing coming from Angle 

Stop Valve to 

Water Source Inlet Port for 

Hydrogen-rich Water.

Faucet Port - 

Filtered Water Only.

No H2 Production

Summary of Contents for The ionpia H2

Page 1: ...from AlkaViva Hydrogen Enhanced Living The ionpia H2 Owner s Manual Warning Incorrect installation and or operation could void your valuable warranty Please protect your investment READ THIS MANUAL CAREFULLY ...

Page 2: ...HYDROGEN GENERATOR H2 Page 2 TABLE OF CONTENTS Safety Precautions Quick Tour of the ionpia H2 Installation Operation Replacing your Filters Product Specifications 03 04 06 10 10 12 ...

Page 3: ... can be used on 110v 240v Always be sure to use the appropriate factory electrical plug Always make sure that the plug is firmly inserted into the outlet Never try to make any modifications to manufacturers original equipment and never use a damaged power cord Be sure that the power adapter is placed where it will not come into contact with water Protect your ionpia H2 from freezing temperatures a...

Page 4: ...age 4 2 Water Dispensing Knob Water Outlet Water Trap Grill Filter Cover Faucet Port for Filtered Water Only No H2 Production Water Source Inlet for H2 Production Quick Tour of The ionpia H2 Back of The ionpia H2 Power Inlet ...

Page 5: ...HYDROGEN GENERATOR H2 Page 5 Overview of The ionpia H2 LED Light Carbon Filter Overflow Tray Water Outlet Flow Control Knob UF Membrane Filter Post Carbon Filter ...

Page 6: ...umbed directly to your cold water line no diverter It is recommended that Method 2 be completed by a licensed plumber Installation Options Make Sure You Have All the Accessories 1 2 3 4 1 Faucet Diverter 2 1 4 White Tubing 3 Adapter and power cord for power connection AC 100 240V DC 12V 5A 4 Instruction Manual 5 Angle Stop Adaptor 6 DigiFlow Meter Before installation please check to ensure you hav...

Page 7: ...the tubing connector Be sure to push it onto the connector as far as it will go This may require a firm push Failure to seat it all the way may cause a leak 6 Slide the compression nut back over the supply line to the diverter valve and thread into place Ensure the nut is screwed firmly in place but do not overtighten Part 1 Part 2 1 Connect the white 1 4 tubing into the Water Source Inlet on the ...

Page 8: ... tubing simply push it firmly into the Water Source Inlet port Give it a gentle tug to ensure proper connection It should not come out To remove tubing press the collet towards the fitting and pull the tubing out at the same time NOTE Use of faucet port is NOT recommended as it will NOT produce Hydrogen rich water only filtered water 4 POSITION YOUR ionpia H2 Ensure it is on a hard and level surfa...

Page 9: ...nd show remaining filter life capacity It will automatically shut off 10 seconds after the water flow stops When no water is being ran through it you can view the remaining filter life by pressing CHECK RESET button The DigiFlow meter counts down meaning it will show you how many gallons are left not how many have been used When the meter reaches zero 0 indicating your filters have expired the Dig...

Page 10: ...flow of water and remove any residual water inside your ionpia H2 3 Open Filter Cover Note If your ionpia H2 is connected directly to your cold water line skip step 1 and start at step 2 1 Turn your tap water onto cold then turn the lever on your diverter valve This will divert the water from the tap to The ionpia H2 At this point check all connections for leaks tighten or re seat if needed If the...

Page 11: ...dle by aligning the grooves Press it in and turn clockwise a quarter turn to lock it into place See Figure 2 6 After installing your new filters close the Filter Cover 7 Turn on source water to the ionpia using either the diverter or the Cold Water Supply 8 It is important to flush the filters before you start drinking the water Do this by running water through the unit for several minutes or unti...

Page 12: ...Water Pressure Allowance Water Temperature External Dimension Weight Filter Rating The ionpia H2 Neutral Water Hydrogen Generator 100 240V DC12V 50 60Hz 65W Mechanical Household drinking water 29 psi 58 psi 40 F 80 F DO NOT USE HOT WATER 5 W x 17 5 D x 13 5 H 9 75 lbs Rated at 700 gallons or 1 year whichever comes first 5 17 5 13 5 6 ...

Page 13: ...Hydrogen Enhanced Living Revision Version Date 7 24 2017 Dealer Information ...

Reviews: