28
After these adjustments, we return to the main menu by pressing the button 4.
SUGESTION: to avoid confusion and unwanted turning on and off, activate only one program if
you are not sure what do you want to accomplish.
Deactivate daily if you wish to engage weekly program. Weekend program always keep inactive, if
using weekly program in levels 1, 2, 3 and 4.
Activate weekend program only after deactivating the weekly program.
15.4.4. Menu 03 – language selection
Provides selection between available languages.
Level 1
Level 2
Value
Menu 03 – choose language
Menu 03-01 – Italian
Set
Menu 03-02 – French
Set
Menu 03-03 – English
Set
Menu 03-04 – German
Set
Attention: English language is set. We recommend that in menu 3 keeps fabric settings.
15.4.5. Menu 04 – stand-by mode
When you choose ON, “STAND-BY” mode activates that shuts the furnace down after the room temperature
reaches 4ºC higher value from set temperature (T
SET
) in a time period longer than 2 minutes.
After shutting down caused by this setting, re-ignition will be possible when following condition is met:
T
room
< T
SET
– 4ºC
If the option ON is activated in stand-by menu, choosing options 1, 2 or 3 it is possible to set that stand-by mode
activates following temperatures:
1 – Room temperature
2 – Water temperature in the boiler
3 – Room thermostat that can measure room temperature (if available).
Attention: We recommend that stand-by mode in menu 4 keeps fabric settings.
15.4.6. Menu 05 – sound signal mode
Choosing “OFF” option acoustic signalisation is disabled.
15.4.7. Menu 06 – initial filling
Enables pre-charge with pellets in shut-down and cold furnace for 90 seconds. Start with pressing push-button P1
and stop with pressing P4.
15.4.8. Menu 07 – furnace status
Shows current furnace status displaying statuses of different devices connected to it. It shows: Flue gasses,
temperature, blower motor RPM etc.
15.4.9. Menu 08 – technical settings
Access to this menu is not available to the User.
15.5. ALARMS
In case of malfunction, controller turns on and warns for irregularities with different kinds of alarms. Following
alarms are envisaged:
Source of alarm
Display message
Smoke temperature probe
PROBE EXHAUST
Smoke temperature exceeding
HOT EXHAUST
Ignition failure
NO LIGHTIN-
Fire extinguishing during work mode
NO PELLET
Power outage
BLACK OUT
Screw feeder safety pressure stat
FAILURE DEPRESS
Safety thermostat
SAFETY THERMAL
Smoke fan malfunction
FAN FAILURE
Screw feeder safety
ALARM TRIAC CO.
Flow meter malfunction
PRESS WATER
Table 6