22
When during the stage of ignition, the stove transfers to the stage of normal operation (stage WORK), it is possible
to adjust the output power, that is, the intensity of heating. By pressing the buttons 5 and 6, the message SET
OUTPUT appears, which means setting the output power. With button 6 we increase and with button 5 we reduce
the power of the stove. Level 1 is minimal and level 5 is maximal power.
Figure 32
15.2.7. Cleaning of the boiler
During normal functioning in the operational mode, in intervals which have been set to 30 minutes, the mode
“BOILER CLEANING” switches on, whose duration is 60 seconds. Then the process of inserting pellets stops and
the burner is cleaned from unburned pellets, which has been followed by a message on the display that says
CLEANING FIRE-POT.
15.2.8. Switching off the stove
In order to switch off the stove, it is sufficient to hold the button 4 pressed for about 2 seconds.
The snail is immediately stopped and the smoke motor transfers to a higher speed and the following message
appears on the display: CLEANING FINAL (figure 33). The stage CLEANING FINAL follows, which last from 10 to
20 minutes.
Figure 33
The activity of the smoke motor ends 10 minutes after the stove switches off and after the smoke temperature has
fallen below the value of 70ºC. When the stove switches off, a message OFF is shown on the display OFF (Figure
34).
Figure 34
15.2.9. Reigniting the stove
It is not possible to reignite the stove before the temperature of the flue gasses falls below the value of
45ºC i.e. until the stove becomes cold.
15.5.
APPEARANCE OF THE FLAME – FIRE
You should pay attention to the shape, color and nature of the fire.
The shape
of fire should be „lively”, elongated and wide.
The color
of fire should be between yellow, light yellow and white color.
The nature
of fire should be „lively”.
15.5.
MENU
By pressing the button 3 (MENU), an access to the menu is provided.
It is divided into different items and levels that enable access to the adjusting and programming of the card.
The items of the menu that approve access to the technical programming are protected with a key.
15.4.1. User’s menu
The following review shortly describes the structure of the menu, in this paragraph only explaining the selections
that are available to the user. The Menu is accessed through the button 3, and then the same button is used for
access to the next level of the submenu and in the end the button 3 is used for setting a value and transition to the
next menu item.