1. T-shaped pipe fittings – T-shaped pipe coupling
2. Cleaning direction
3. Opening, window for servicing / inspection
4. Cleaning direction
5. T-shaped pipe fittings – T-shaped pipe coupling
6. Cleaning direction
7. Sealed cover for the purpose of cleaning (plug)
D A
S M E R
D I M A
N E
Figure 7.Flue pipe installation
It is recommended that knee-shaped flue pipes are three-fold to minimise the resistance of smoke passage. It is
also recommended that one of the
used knees and positioned in a suitable place has an opening for easier and
more efficient cleaning of flue pipes. See image 7a.
Figure 7a
Insulation thickness
mm
Flue pipe diameter (mm)
D.80
D.100
Diameters of holes (openings) that should be
made (mm)
Walls made of wood or combustible
anyway, or parts that are combustible
100
150
170
Concrete wall or roof
50
100
120
Brick wall or roof
30
100
120