Troubleshooting Chart | 43
WWW.ALEMITECARbONSHIELD.COM
troubleshooting chart
Problem
Possible cause
Possible solution
Any Sensor out of range
alarm in the HMI.
1. Sensor failure is very
unlikely. The Carbon
Shield control system
continously monitors all
parameters involved in
oil mist generations. As
a result, the HMI could
display more than one
fault for the same problem
.
1. The replacement of Sensors is out of the
scope of this manual. Please change over
from the main unit to the backup unit. Turn
off the power to the main unit and contact
Customer Service at 1-800-822-4579.
Insufficient amount of oil
mist or no mist produced
(Potential problem may
be unrelated to the
Carbon Shield Unit
internal workings)
1. Distribution line
obstruction
2. Console Reservoir
overfilled
3. Foreign material in
application fitting(s)
4. Improper oil or
incompatible oils
1. Remove low spots in distribution line.
2. Consult with Alemite® Technical Service.
3. Clean distribution vent line(s).
4. Clean or replace application fitting(s).
5. Check with supplier on oils specific
for oil mist lubrication.