Switching from Main
to backup Generator
Follow the process described below to dampen
the transient pressure resulting when the main
generator is shut down and backup generator
starts: (Fig. 87)
1. Open the mist outlet valve of the backup unit
2. Switch the 3 way air inlet valve to supply air
to the backup generator
3. Close the main unit mist outlet valve
to switch back to the main generator the
process is reversed:
1. Open the mist outlet valve of the main unit
2. Switch the 3 way air inlet valve to supply air
to the main generator
3. Close the backup unit mist outlet valve
Fig. 87