• For systems with the optional auto-refill
package, open the ball valve in the incoming oil
line (left side of the oil mist reservoir). (Fig. 38)
• Turn on the air supply to the refill pump.
(located at the bulk oil tank)
start-up sequence
1. Adjust internal pressure regulator inside
cabinet to 80 psi (5.63 kg/cm2). (Fig. 37)
2. Turn on power to the oil mist unit with the main
power switch at the lower left side inside the
cabinet. (Fig. 39) This energizes the PLC and HMI.
3. As unit is starting up, observe HMI display. Four
choices are displayed on the HMI. Transfer,
Start, Control Panel and Task bar (Fig 41)
3a. Choose “Start,” or wait for the Alemite home
screen to show. (Fig 42).