44 | alemite Carbon Shield Service Guide
www.alemitecarbonshield.com
specifications
Mechanical systems
console
Height*
58.9 in. (149.6 cm)
Width*
35.5 in (90.2 cm)
Depth*
37.6 in (95.5 cm)
Material
Stainless Steel
Enclosure Rating
NEMA 4X
Cabinet Cooling
Optional, vortex system
Cabinet Purge
Optional
Environment
Class I, Division 2,
Groups b, C, and D, T4
Generator
Nozzle CFM
1, 2.3, 4.3, 9.7, 13, 21
back-up
Optional
Reservoir
Capacity
3 and 5
Material Stainless Steel
oil heater
Power
500 Watt
Nominal Temp.
100° F (37.8° C)
Temp. Range
80-140° F (26.7-60.0° C)
* Typical (with back up generator and 5 gallon, or 18.9 L, reservoir)
Air heater
Power
500 or 1000 Watt
Nominal Temp.
100° F (37.8° C)
Temp. Range
0-180° F (-17.8 to 82.2°C)
Air supply
Pressure Range
70-150 psi
(4.92-10.55 kg/cm
2
)
Quality
Instrument air, Dry
Regulated air pressure to generator
Nominal
80 psi (5.63 kg/cm
2
)
Min/Max
65/95 psi**
(4.57-6.68 kg/cm
2
)**
Mist Pressure Head
Nominal
20 Inches H2O
Range
10-40 Inches H2O
(depending on the
nozzle size)
bulk oil tank (Accessory)
Capacity
110 Gallons (416 L)
**13 & 21 CFM Nozzles require 90-95 psi
(6.33-6.68 kg/cm
2
)
Potentially Hazardous conditions
May result in death, severe injury, or equipment damage.
All electrical components are rated for Class I, Division 2 hazardous locations. Substitutions will void
the hazardous locations rating of the Carbon Shield
™
System.
REfEREncE
Summary of Contents for Carbon Shield
Page 1: ...INSTALLATION OPERATION AND MAINTENANCE MANUAL ...
Page 2: ......
Page 4: ...2 www alemitecarbonshield com Fig 01 ...
Page 5: ...Alemite Carbon Shield Service Guide 3 www alemitecarbonshield com Fig 02 ...
Page 39: ...Alemite Carbon Shield Service Guide 37 www alemitecarbonshield com ...
Page 57: ...References Installed Arrangement Fig 95 Fig 95 www alemitecarbonshield com ...