9 — Connecting to external alarm equipment
9-4
2902 MainStreet Technical Practices
90-2906-01 May
2002
Procedure 9-1 To make connections for monitoring external alarm
devices
Tools required:
•
one RJ11-to-spade lug cable, or
•
one RJ11-to-RJ11 cable and a distribution box
1
Attach one end of the RJ11 cable to the Alarm connector.
2
Attach the other end of the cable.
a
For an RJ11-to-spade lug cable, connect pins 1 and 2 to the monitoring
terminals of your device. Pin 1 is ground.
b
For an RJ11-to-RJ11 cable with a distribution box, connect the RJ11 connector
to the box, then connect the proper box terminals to the monitoring terminals
of your device.
Procedure 9-2 To make connections for activating external alarm
devices
Tools required:
•
one RJ11-to-spade lug cable, or
•
one RJ11-to-RJ11 cable and a distribution box
1
Attach one end of the RJ11 cable to the Alarm connector.
2
Attach the other end of the cable.
a
For an RJ11-to-spade lug cable, connect pins 3 and 4, or pins 5 and 6 to the
activation terminals of your device.
b
For an RJ11-to-RJ11 cable with a distribution box, connect the RJ11 connector
to the box, then connect the proper box terminals to the activation terminals of
your device.
Summary of Contents for MainStreet 2902
Page 1: ...2902 MainStreet Network Termination Unit Release 1 0 H T E C H N I C A L P R A C T I C E S ...
Page 40: ...3 Mounting the unit 3 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 50: ...4 Ground and power connections 4 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 68: ...6 Connecting to the network 6 4 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 90: ...7 Connecting to data devices 7 22 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 108: ...10 Node management 10 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 150: ...14 CPSS 14 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 218: ...20 Codirectional DCM 20 6 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 234: ...22 HCM rate adaption 22 10 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 246: ...23 Cross connecting circuits 23 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 254: ...24 Visual indicators 24 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 266: ...25 Alarms 25 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 278: ...26 System diagnostics 26 12 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 298: ...27 Loopbacks 27 20 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 332: ...Glossary GL 8 2902 MainStreet Technical Practices 90 2906 01 May 2002 ...
Page 343: ......
Page 344: ... 2002 Alcatel All rights reserved 90 2906 01 95 1820 01 00 C ...