NOTE FOR THE REPLACING OF MEMORY IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE
•
•
Initial Data setting will not be possible if clock has been set. To reset clock, either unplug AC cord and allow
at least 30 minutes before Power On or alternatively, discharge backup capacitor.
No need the setting for after INI 6.
INIT 01 EB
ADDRESS DATA
Table 1
INI
01
DATA
ADDRESS
INI
02
INI
04
INI
05
INI
06
CB
91
09
80
88
AD
INI
03
1.
2.
3.
Enter DATA SET mode by setting VOLUME to minimum.
While holding down VOLUME button on front cabinet, press key 6 on remote control simultaneously.
ADDRESS and DATA should appear as FIG 1.
Fig. 1
ADDRESS is now selected and should "blink". Using the SET + or - keys on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
Press ENTER to select DATA. When DATA is selected, it will "blink".
Again, step through the DATA using SET + or - until required DATA value has been selected.
Pressing ENTER will take you back to ADDRESS for further selection if necessary.
Repeat steps 4 to 7 until all data has been checked.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
4.
5.
6.
7.
8.
9.
The unit will now have the correct DATA for the new MEMORY IC.
C3-1