RATING CONDITIONS
Revision 0
3-1
3.
RATING
CONDITIONS
Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
Cooling:
Indoor: 27
o
C DB 19
o
C WB
Outdoor: 35
o
C DB
Heating:
Indoor: 20
o
C DB
Outdoor: 7
o
C DB 6
o
C WB
3.1
Operating
Limits
3.1.1 R410A
Indoor
Outdoor
Upper limit
32
o
C DB 23
o
C
WB 46
o
C DB
Cooling
Lower limit
21
o
C DB 15
o
C
WB 10
o
C DB
Upper limit
27
o
C DB
24
o
C DB 18
o
C WB
Heating
Lower limit
10
o
C DB
-9
o
C DB -10
o
C WB
1PH
198 – 264 V
Voltage
3PH
360 – 440 V