5. Periodic Inspection
5-10
5.4.9 Check Thermo-Label on the Generator
Every 2 months or 250 Hours
Thermo-label on the rotor bearing irreversibly changes its color from white to blue by reaching or
exceeding 176°F (80°C). Be sure to check the bearing for abnormal noise and vibration if it has
changed color.
A160168-1
Replace thermo-label if it has changed color.
When replacing, contact your nearest dealer.
5.4.10 Drain Fuel Tank
Every 250 Hours
A180832
To drain fuel tank, remove drain plug [B], and open
drain valve [C] to drain the condensate accumulated
in fuel tank [A].
After making sure that all condensate is completely
drained out, close drain valve firmly and install drain
plug [B].
Drain the condensate into a container [D] and dispose
of condensate according to applicable regulations.
5.4.11 Change Fuel Filter Element
Every 500 Hours
A130074
<Procedure>
1.
Turn the lever [A] of fuel filter to [OFF] and cut off
fuel supply.
2.
Remove the cup
[C]
after loosening the ring nut
[B],
and then take off the element
[D]
from the inside.
3.
Clean the cup
and then install the new element
and
O-ring
[E],
[F].
(For part number, See 5.3)
4.
Install to the body the cup
equipped with the
element. Then tighten the ring nut
securely.
5.
Turning lever of fuel filter to [ON] position, supply
fuel in the cup. Then bleed air completely from fuel
system
.
(See 3.6.6)
A
B D
C
Thermo-Label
ON
OFF
A
F
D
E
C
B