3. Operation
3-9
3.5.2 Check Coolant Level
H000036
Check the coolant level in the surge tank. If it is lower than the
limit, open the cap and refill the coolant.
(Level must be kept above LOW.)
If the coolant in the surge tank is exceedingly low or empty,
remove the radiator cap and check the amount of coolant in the
radiator. Refill coolant within the radiator and surge tank.
(See 5.4.20)
H990432
When removing the radiator cap, lightly turn it and release the
internal pressure without completely opening it once the first stage
lock is released. After confirming that the internal pressure has
been released, turn it off while pushing in until the second stage
lock is released.
If this procedure is neglected, its inner pressure can blow off the
radiator cap, and steam jetting out of the radiator could cause
scalding.
Do not operate the machine without sufficient coolant. Insufficient coolant can cause air bubbles to form
and damage the radiator.
LOW
Cap
Reserve tank