AirLive
POE100CAMv2
User’s
Manual
51
Sensor input 1
:
Click it on for using external sensor which is connected to sensor input1 of the camera I / O
port.
¾
Trigger condition
: Select High signal output and Low signal output as your alarm.
¾
Camera move
: Pull down the window to select the camera preset position.
6.2.9 Alarm buffer
You can set the Pre-alarm image and audio (the image and audio before the alarm detection) and the Post -
alarm image and audio. These can be set when
Alarm sending
FTP client setting menu or Image memory
setting menu is set to
On
, and besides when
Use alarm buffer
is selected.
6.2.10 Setting
Alarm buffer
: To activate the Alarm buffer function, select
On
. The basic setting options are displayed below.
When you do not use the Alarm output function, select
Off
.
¾
Recording capacity
z
Pre-alarm period
:
Display the maximum recording capacity of image/audio before the alarm
detection.
z
Post-alarm period
:
Display the maximum recording capacity of image/audio after the alarm
detection.