22
The View Data tab allows you to look at the collected data and the trace file. This data
can be exported to Excel as a .csv file and displayed by Excel charts
The trace file displays the data in a torque/time graph and allows the user to supersede
the move-on reading selected by the wrench by visually discerning via the trace where
the fastener started to rotate. When selecting a single job, the average, range, sigma, Cp
and CpK values are listed.