background image

14 

5.  When  the  desired  value  is  selected, 

press 

ENTER

 to save and progress to 

the next 

MENU

 level. 

 

At any 

Menu

 level, pressing 

ENT

 twice will 

return  to  the  Main  Display  Screen  at  the 
previously set 

Operating Mode.

 

 

 
(2-4) End Timer 

The  Auditor™  family  of  products  shares 
software with other items in the Auditor™ 
line. The End Timer has no purpose with 
the 

AUET

 products. 

 
Settings  in  this  screen  have  no  effect 
on the operation of the tester. 
 

Press 

ENTER

  to  progress  to  the  next 

MENU

 level.

 

 

At any 

Menu

 level, pressing 

ENT

 twice will 

return  to  the  Main  Display  Screen  at  the 
previously set 

Operating Mode

 

 
 
(2-5) Sign Lock 

The 

SIGN  LOCK

  feature  allows  the  user 

to  select  the  rotation  direction  in  which  a 
torque  peak  will  be  captured.  With 

SIGN 

LOCK

  set  to 

ON

,  the  initial first  rundown 

direction is set as the default direction.  
 
If  the  initial  rundown  was  performed  in  a 
clockwise  direction  a  positive  reading 
indicates a reading taken in the clockwise 
direction  while  a  negative  torque  value 
indicates  a  reading  taken  in  the  counter-
clockwise direction. If the initial rundown is 
taken in a counter clockwise manner, then 
the  opposite  will  hold  true.  Any  readings 
taken in the non-selected direction will be 
measured, but not captured / displayed as 
a peak value. 
 
With 

SIGN  LOCK

  turned 

OFF

,  peak 

values in both the clockwise and counter-
clockwise  directions  will  be  captured  and 
displayed. 
  
Since 

most 

torque 

rundowns 

are 

conducted  and  readings  are  taken  in  the 
clockwise  direction,  the  user  may  find  it 
beneficial to turn this feature 

ON

Turning Sign Lock ON / OFF 

1.  From the main display press 

MENU

 

2.  Press  the 

Right  Selection

  button  to 

select 

PEAK OPTIONS MENU

 

3.  Use  the 

Selection  Arrow

  buttons  to 

select 

SIGN LOCK

 

4.  Use  the 

Left  Selection  button

  to 

toggle 

SIGN LOCK

 on or off. 

5.  When  the  desired  value  is  selected, 

press 

ENTER

 to save and progress to 

the next 

MENU

 level. 

 

At any 

Menu

 level, pressing 

ENT

 twice will 

return  to  the  Main  Display  Screen  at  the 
previously set 

Operating Mode

 

 
 
Resetting Sign Lock 

If 

SIGN  LOCK

  is 

ON

  and  the  rotation 

direction needs to be reset turn the 

AUET 

OFF

  then  turn  the 

AUET

  back  on  and 

follow the above procedure. 

 
 
(2-6) Edit Limits 

By  using  the 

EDIT  LIMITS

  feature  to  set 

high and low limits for torque readings, the 
user 

can 

receive 

visual 

feedback 

regarding the rundown results. 
 
Setting  the 

HIGH

  and 

LOW

  limits 

appropriately  will  result  in  the  following 
display signals: 
 
Reading 

outside

 of set limits: 

  A 

RED

  LED  being  lit  on  the 

AUET

 

(

Next to 

OFF

 button)

 

 

  A 

 symbol for 

LOW

 readings and a 

  symbol  for 

HIGH

  readings  being 

displayed on the screen 

(Figure 1)

  

 
Reading 

within

 set limits: 

 

  A 

GREEN

 LED being lit on the 

AUET

 

(

Next to 

ON

 button

(Figure 1

 

 
Setting High and Low Torque Limits 

1.  From the main display press 

MENU.

 

2.  Press  the 

Right  Selection

  button  to 

select 

PEAK OPTIONS MENU.

 

3.  Use  the 

Selection  Arrow

  buttons  to 

select 

EDIT LIMITS.

 

Summary of Contents for AUDITOR AUET

Page 1: ...AUET AUET MTM DC Desktop Torque Testers User Guide ...

Page 2: ...atistical Information 11 AUET DC Menu Functions Accessing Menu Functions 12 Peak Options Menu Accessing the Peak Options Menu 12 Auto Clear 13 Setting Auto Clear 13 Filter 13 Setting the Filter Value 13 Peak Blanking 13 Setting the Peak Blanking Value 13 End Timer 14 Sign Lock 14 Turning Sign Lock On Off 14 Resetting Sign Lock 14 Edit Limits 14 Setting High and Low limits 14 System Menu Accessing ...

Page 3: ...g parts Damaged or entangled cords increase the risk of electric shock e When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock 3 PERSONAL SAFETY a Stay alert watch what you are doing and use common sense when operating a power tool Do not use a power tool while you are tired or under the influen...

Page 4: ...must be repaired c Do not exceed transducer torque value or the rated torque value of joint rundown kit Applying excess torque will damage transducer and joint rundown kit UNIT SPECIFICATIONS AUET Dimensions Width 4 75 Height 3 75 w o Joint Simulator Depth 5 0 Weight 5 15 Lb Power Requirements Main power 100 240VAC 60hz from supplied charger or internal NiMH battery pack Operating Temperature Rang...

Page 5: ...enu Screen 11 OK Rundown Charging Mode Indicator LED GREEN 12 Right Selection Button Data Storage Mode Increase Parameter Value Select Parameter 13 Selection Arrow Up Change Engineering Units Scroll Up through Parameter Screens 14 Data Storage Mode Status 15 Engineering Unit Status 16 All Clear Status Indicator Absent when A C turned OFF 17 Menu Screen Indicator Stored Rundown Number 18 Angle Puls...

Page 6: ...6 Figure 2 Figure 3 AUET MTM AUET Model Model Transducer Selection Transducer Input AUET MTM DC DC Power Input Serial Communication Output Serial Communication Output DC Power Input ...

Page 7: ...n DC mode Battery and the battery charge is low the symbol low battery will show on the Main Display screen see Figure 1 19 The 100 240VAC Charger should be plugged into the unit immediately to continue uninterrupted operation Basic Navigation and Use of the Keypad Many functions of the Auditor AUET Desktop Torque Tester can be accessed by using the button directly below the associated text on the...

Page 8: ...reads Place the square drive end of the simulator into the female square drive on the AUET Tester BASIC FUNCTIONS OPERATING MODE Descriptions By selecting the proper Operating Mode the user can properly take torque readings from a variety of manual and powered tools PEAK This mode will provide a display of the maximum torque value achieved by the tool during operation This mode is used for all con...

Page 9: ...urn to the RUN mode no storage the DOWN arrow should be pressed repeatedly until the memory location indicator goes to 000 and disappears Pressing the MEM menu key will then return the unit to RUN mode Setting ENGINEERING UNITS The AUE MTM DC must be in RUN MODE in order to change the Engineering Units If torque values have been stored in the AUET MTM DC while in MEMORY MODE then the memory must b...

Page 10: ...l not store any of the following rundown values To switch the unit to MEMORY MODE from RUN MODE press the RIGHT SELECTION BUTTON Figure 1 and verify that MEM is displayed in the DATA STORAGE MODE field Storing Rundown Torque Values 1 Enter MEMORY MODE 2 Press the SELECTION ARROW UP button to scroll to memory position 1 which will be indicated by a 001 in the Stored Rundown Number field Figure 1 Th...

Page 11: ... values that have been stored in MEMORY MODE 1 Enter MEMORY MODE 2 Using the SELECTION ARROW buttons scroll UP or DOWN through the list of stored rundown values It is possible to scroll to a stored rundown number which is above the highest stored value for example if 10 rundowns have been stored it is possible to scroll to stored rundown number 15 however all rundown values above 10 will display a...

Page 12: ...e screen From this screen the SELECTION ARROW buttons can be used to access the individual menu options By pressing the button the menu options will display in the following order I Link to PC Link to PC executes the communication between the tester and the PC II Peak Options Menu Accessing the PEAK OPTIONS menu 1 From the Main Display screen press MENU 2 PEAK OPTIONS MENU should be displayed If i...

Page 13: ... most reliable readings The values are shown in values from 125 2000 Hertz Hz A general starting point for programming is 500 Hz for most but more consistent values may be obtained with other settings depending on tool design joint characteristics and other factors Setting the Filter Value 1 From the main display press MENU 2 Press the Right Selection button to select SEL PEAK OPTIONS MENU 3 Use t...

Page 14: ...clockwise directions will be captured and displayed Since most torque rundowns are conducted and readings are taken in the clockwise direction the user may find it beneficial to turn this feature ON Turning Sign Lock ON OFF 1 From the main display press MENU 2 Press the Right Selection button to select PEAK OPTIONS MENU 3 Use the Selection Arrow buttons to select SIGN LOCK 4 Use the Left Selection...

Page 15: ...g above the LOW LIMIT will generate a GREEN LED signal If LOW is disabled only values above the HIGH LIMIT will generate a RED LED signal Any value below the HIGH LIMIT will generate a GREEN LED signal 8 Once the selected limit is set press ENTER to return to the EDIT LIMITS screen 9 To select and edit the other limit proceed as above 10 Once either or both limits have been set press ENTER to retu...

Page 16: ...NU 3 Press the Right Selection button to select SEL SYSTEM MENU 4 Use the Selection Arrow buttons to scroll to LOCKOUT MENU 5 Press the Right Selection button to select SEL LOCKOUT MENU 6 The user can then use the SELECTION ARROW buttons to scroll through the following options in the order shown 7 Use the Left and Right Selection buttons to turn each lockout mode ON or OFF separately 8 Once all LO...

Page 17: ...CO s Part RS232C The data can be transmitted to a serial printer or to a terminal emulation program on the user s computer PC such as Hyper Terminal Connection to a serial printer requires a NULL Modem adapter RS232 Transfer Protocol Single Direction Cable 9 pin to mini plug Protocol Value Baud Rate 9600 Parity None Bits 8 S bit 1 Flow None Data Stream Format mmmbsdddddbuuuuucl m memory location s...

Page 18: ... below AUDIT MODE is entered by pressing AUDIT button The tester will prompt for a USER NAME which can be entered from the display using the blue scroll keys to drive the cursor to letters numerals Once highlighted by the cursor user presses the ENT button to select When finished entering USER NAME press the blue oval button under DONE text Tester will advance to a list of tools for testing Use bl...

Page 19: ...n The applications have been designed to be simple powerful and flexible It is open so MIS or engineers familiar with database queries can retrieve tools jobs routes and data quickly and efficiently AWS Tool Manager 1 Main Screen Auditor Tool Manager Tool Builder Tool info drop down list shows available Tools You can also select New Copy Edit or Delete When you highlight the Tool details are liste...

Page 20: ...20 The View Data tab allows you to look at the collected data and see whether the tool passed or failed This data can be exported to Excel as a csv file and displayed by Excel charts ...

Page 21: ... Route Info lists all Routes and the Jobs in a Route You can select New Copy Edit or Delete for Routes When you highlight the Route and the Job in the Route the Job details are listed in the window on the far right The large button on the center bottom of this screen sends the selected Route to the wrench After collecting the data the button on the bottom right allows you to upload data Jobs and R...

Page 22: ...sv file and displayed by Excel charts The trace file displays the data in a torque time graph and allows the user to supersede the move on reading selected by the wrench by visually discerning via the trace where the fastener started to rotate When selecting a single job the average range sigma Cp and CpK values are listed ...

Page 23: ...AIMCO Distributor or authorized AIMCO Sales Representative for a transducer upgrade quotation For the typical Industry Standard IS type of transducer the setup procedure is as follows 1 Turn the AUET MTM On 2 Within 3 seconds of pressing the ON button press the LEFT SELECTION BUTTON Figure 1 for CAL 3 Press ENT to SELECT UNITS If a transducer has been previously setup the data for that previous se...

Page 24: ...s value Hit ENT once the desired value is displayed 10 Press the DOWN SELECTION ARROW to set the Cal Confirm Cal by hitting ENT Repeat steps 8 9 11 After mV V and Full Scale have been entered the display returns to the A D count screen Hit ENT 12 If the value is correct press ENT and PGM will show on the screen 13 Press the LEFT SELECTION BUTTON to Save the setting The unit will power itself off a...