26
ANET1553
Users
Manual
3.1.8.1 Direct Coupling
Direct Coupling
connects the subsystem/terminal device
directly to the bus and can only be used in connections
under one foot in length.
Since a Direct Coupled stub provides only limited isolation
in the event of a device (subsystem or terminal) short,
Transformer Coupling is normally the recommended
method of connecting to the bus.
Figure 3-16 Pigtail Connector
AIM provided Pigtail Connector
A B
AIM Module
T
T
T
T
Terminators
A B
Bus A
Bus B
Stub Length One Foot Max
Figure 3-17 Direct Coupling