27
107110-01 - 6/16
Option
10
11
12
13
14
15
16
17
Illustrated in Figure
7.15, 717 7.15, 7.17 7.17, 7.18 7.17, 7.18
7.17
7.17
7.17
7.17
Pipe
Penetration
through
Structure
Vent
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Intake
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Roof
Material
Vent
CPVC/
PVC
(Note 2)
CPVC/
PVC
(Note 2)
DuraVent
PolyPro
(Rigid)
DuraVent
PolyPro
(Rigid)
Selkirk
Polyflue
Selkirk
Polyflue
Centro-
therm
InnoFlue
SW
Centro-
therm
InnoFlue
SW
Intake
PVC
PVC
PVC
PVC
PVC
PVC
PVC
PVC
Nominal
Diameter
Vent
2”
3”
2”
3”
2”
3”
2”
3”
Intake
2”
3”
2”
3”
2”
3”
2”
3”
Min Equivalent Vent Length:
Models
K2WT-080
12”
12”
12”
12”
12”
12”
12”
12”
K2WT-100
12”
12”
12”
12”
12”
12”
12”
12”
K2WT-120
Not
Permitted
12”
Not
Permitted
12”
Not
Permitted
12”
Not
Permitted
12”
K2WT-150
52”
52”
52”
52”
K2WT-180
52”
52”
52”
52”
Max Equivalent Vent Length (Note 1):
Models
K2WT-080
60ft
135ft
60ft
135ft
60ft
135ft
60ft
135ft
K2WT-100
60ft
135ft
60ft
135ft
60ft
135ft
60ft
135ft
K2WT-120
Not
Permitted
135ft
Not
Permitted
135ft
Not
Permitted
135ft
Not
Permitted
135ft
K2WT-150
135ft
135ft
135ft
135ft
K2WT-180
135ft
135ft
135ft
135ft
Terminal Option H
(Fittings)
Vent
Coupling
w/Screen
Coupling
w/Screen
2PPS-12B
or
2PPS-36B
w/Screen
3PPS-12B
or
3PPS-36B
w/Screen
2PF-10UV
or
2PF-39UV
w/Screen
3PF-10UV
or
3PF-39UV
w/Screen
ISEP02 or
ISEP0239
w/Screen
ISEP03 or
ISEP0339
w/Screen
Intake 180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
180 Elbow
w/Screen
Terminal Option i
(Ipex FGV Concentric)
Ipex
196105
(Note 3)
Ipex
196006
(Note 3)
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Terminal Option J
(DiversiTech CVENT
Concentric)
CVENT-2 CVENT-3
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Terminal Option K
(DuraVent Vertical
Concentric)
Not
Permitted
Not
Permitted
2PPS-VK
3PPS-VK
Not
Permitted
Not
Permitted
Not
Permitted
Not
Permitted
Notes:
1. Max vent lengths shown also apply to the intake. For example, Vent Option #1 may have up to 60ft of vent pipe and also up to 60 ft of i
intake pipe.
2. First 30” of vent and vent Elbow connected to boiler must be CPVC. Downstream vent pipe can be PVC except as noted in text.
3. Ipex FGV Concentric Terminal available in various lengths and also CPVC (see text).
All vertical terminals require compatible roof flashing and storm collars.
Vii. Venting
C. Design Requirements Unique to Vertical Venting Systems (continued)
Table 7.13a: Summary of Vertical Twin Pipe Venting Options
Summary of Contents for K2WT
Page 82: ...82 107110 01 6 16 Figure 10 4 Proper Installation of Header Sensor X Wiring continued ...
Page 83: ...83 107110 01 6 16 X Wiring continued Figure 10 5 Internal Ladder Diagram ...
Page 84: ...84 107110 01 6 16 X Wiring continued ...
Page 85: ...85 107110 01 6 16 Figure 10 6 Internal Wiring Connections Diagram X Wiring continued ...
Page 95: ...95 107110 01 6 16 Lighting and Operating Instructions XI Start Up and Checkout continued ...
Page 140: ...140 107110 01 6 16 XV Repair Parts continued ...
Page 142: ...142 107110 01 6 16 XV Repair Parts continued ...
Page 146: ...146 107110 01 6 16 XV Repair Parts continued ...
Page 148: ...148 107110 01 6 16 XV Repair Parts continued ...
Page 161: ...161 107110 01 6 16 ...
Page 162: ...162 107110 01 6 16 ...
Page 163: ...163 107110 01 6 16 ...