Operation Instruction
-40-
2.18.2.2 Faults and solutions of generator
Symptom
Reason
Solutions
1.Generator fails to
generate electricity
1.The connection is in error or
broken, or it is in bad contact;
2.The rotor coil is broken;
3.The rectifier diode is damaged;
4.The carbon brush is in bad
contact;
5.The adjuster is damaged.
1.Inspect and repair circuit;
2.Inspect and repair or replace generator
assembly;
3.Replace the diode;
4.Remove dirt or replace the carbon
brush;
5.Repair or replace the adjuster.
2.Generator is
undercharged
1.V-transmission belt is loose;
2.The carbon brush is in bad
contact and the slip ring is
stained with oil;
3.The adjuster is damaged;
4.The battery has been aged.
1.Adjust the V-transmission belt make it
tight;
2.Adjust the carbon brush and clean the
slip ring;
3.Replace the adjuster;
4.Replace the battery.
3.Charging current of
generator is too strong and
the bulb is prone to be
burned out
1.The adjusting voltage of
adjuster is too high;
2.The magnetizing coil of
adjuster is sealed off and has lost
adjusting action.
1.Adjust the voltage to an appropriate
value as required;
2.Inspect and repair the magnetizing coil
and reweld the points of weld.
2.18.2.3 Faults and solutions of battery
Symptom
Reason
Solutions
1.The battery
capacity is
not enough
and it is
hard to
start
engine
1.The electrolyte level is too low;
2.It is short circuit between pole plates;
3.The pole plates are vulcanized;
4. The circuit joints are in bad contact and there
are many oxides on terminals to make battery
undercharged.
1.Add distilled water or 1:1 dilute
sulfuric acid solution;
2.Remove deposits and replace
electrolyte;
3.Charge and discharge again and
again to remove vulcanization;
4. Fasten the joints and remove oxides,
and apply Vaseline to terminals.