84
12.5.4 Calibrating the motors
1. Open the home screen.
2. Press button (1)
Settings
to open the settings screen.
3. Press button (2)
Calibration access
to open the settings screen.
For each dose to be calibrated:
4. In field (3)
Metering unit
, select the metering unit that you want to calibrate.
5. In field (4)
Mode
, select
Manual
mode.
6. Press the
Calibration
button on the machine
.
7. Weigh the actual amount extracted during the calibration process.
8. In field (5)
Valued weighed
, enter the actual value weighed.
Note :
if the calculated
Deviation
is greater than 5%, repeat the calibration.
9. Check that the
Min
and
MaxSpeeds
are consistent.
10. Press button (6)
Confirm
to validate the calibration.