67
12.4.3.2 Configuring and calibrating metering units
1. From the work page, press button (1)
Settings
.
2. Press button (2)
Metering units
to configure and calibrate the metering units.
3. Select the dispenser to be configured by pressing the corresponding
Metering unit X
button (3).
4. Set the various parameters:
- (4) Metering unit name
- (5) Flow test start button
- (6) Calibration list (access to old measurements)
- (7) Number of grams per revolution of the metering unit motor
- (8) Minimum and maximum permitted working speed
- (9) Information on the installed spline
- (10) Number of revolutions per minute of the metering unit (this speed must be between 30 and 70 rpm)
- (11) Desired quantity (in kg) per hectare
- (12) Target working speed
Summary of Contents for Big Boss