83
12.5.3 Calibrating the radar
1. Accurately identify a length of 100m in the field.
2. Put the machine in the working position.
3. Press button (1)
Speed settings
.
4. Select the speed source:
(2) Tractor
(3) Radar (by default)
(4) Simulation
Note
: In simulation, introduce the simulated speed to be used to test the machine in static mode.
5. Press button (5)
Calibration start
.
6. Cover the 100m distance marked in the field and stop at the end.
7. Press button (6)
Confirmation
.
Summary of Contents for Big Boss