5 SPECIFICATIONS
5.1 SPECIFICATIONS
TABLE 5-1. SYSTEM DATA
ITEM
ANACONDA TC50-336
ANACONDA TC50-640
Magnification
Unity (1x)
Objective Lens Type
Germanium
Detector
FLIR Tau 2 17μm Uncooled
Microbolometer
FLIR Tau 2 17μm Uncooled
Microbolometer
Resolution
336x256
640x512
Frame Rate
60 Hz
30 Hz
Display Resolution
800×600
Display Brightness
Discretely Adjustable to 8 Levels
Turn-on Time, max
3 sec
Temperature Imaging Modes
(Image Palettes)
White Hot, Black Hot, Fusion, Rainbow, Globow,
Ironbow 1, Ironbow 2, Sepia, Color 1, Color 2,
Ice-Fire, Rain, and OEM
User-adjustable Image
Enhancement Tools
• Active Contrast Enhancement (ACE) - “CONTRAST”
• Second Generation Digital Detail Enhancement (DDE) –
“SHARPNESS”
• Smart Scene Optimization (SSO) – “SMART SCENE”
• Automatic Gain Control (AGC) - “GAIN”
• User-Controlled Manual Non-Uniformity Correction /
Flat-Field Correction (UCMNUC/FFC)
• Silent Shutterless NUC ™ (SSN)
Boresighting
Accuracy
Factory aligned to 1 MOA or better
Retention
Permanent to within 2 MOA or better
Repeatability
Within 2 MOA
Analog Input/Output Format
(Resolution)
NTSC
*
(640×480 pixels) / PAL (768×574 pixels)
Interfacing
• Micro-USB (Power bank 5V)
• Universal S620 connector (Power In, Analog Video
In/Out, Wi-Fi Attachment, HD Recorder, Extended
Battery Pack
)
* Default setting