Chapter 5
105
Dual Arbitrary Waveform Generator
Using Waveform Markers
To Place Repetitively Spaced Markers within a Waveform Segment
If you have not created a waveform segment, complete the steps in the previous sections,
“Generating the
First Waveform” on page 100
and
“Creating the First Waveform Segment” on page 100
.
1. Press
Mode
>
Dual ARB
>
Waveform Segments
.
2. Press
Load Store
.
3. Highlight a waveform segment (for example,
TTONE
).
4. Press
Waveform Utilities
>
Set Markers
>
Set Marker On Range Of Points
.
5. Press
First Mkr Point
>
10
>
Enter
.
6. Press
Last Mkr Point
>
163830
>
Enter
.
7. Press
# Skipped Points
>
2
>
Enter
.
8. Press
Apply To Waveform
.
NOTE
The last marker point must be greater than or equal to the first marker point.
This activates Marker 1 (selected by default) every three points from point 10 to point 163830 in the selected
waveform segment.
To Use Marker 2 to Blank the RF Output
If you have not created a waveform segment, complete the steps in the previous sections,
“Generating the
First Waveform” on page 100
and
“Creating the First Waveform Segment” on page 100
.
NOTE
RF blanking applies to Marker 2 only. Marker 1 does not blank the RF output. For more
information, see
“Waveform Marker Concepts” on page 108
.
1. Press
Preset
.
2. Press
Mode
>
Dual ARB
>
Select Waveform
.
3. Highlight a waveform segment (for example,
TTONE
).
4. Press
Select Waveform
.
5. Press
Mode
>
Dual ARB
>
ARB Setup
>
Mkr 2 To RF Blank Off On
.
6. Press
Return
>
Arb On Off
to On.
7. Press
Waveform Segments
>
Load Store
>
Waveform Utilities
>
Set Markers
>
Marker 1 2
>
Set Marker On Range of Points
.
8. Press
First Mkr Point
>
10
>
Enter
.
9. Press
Last Mkr Point
>
163830
>
Enter
.
10. Press
Apply To Waveform
.
Summary of Contents for E8247C
Page 10: ...Contents x ...
Page 96: ...86 Chapter 4 Analog Modulation Configuring the LF Output ...
Page 142: ...132 Chapter 6 Custom Arb Waveform Generator Working with Filters ...
Page 178: ...168 Chapter 7 Custom Real Time I Q Baseband Working with Differential Data Encoding ...
Page 198: ...188 Chapter 10 Troubleshooting ...
Page 214: ...204 Chapter 10 Troubleshooting Returning a Signal Generator to Agilent Technologies ...