OVERVIEW

The Microscan BCR (

B

ar 

C

ode 

R

eader) scanner (FIS 610-0018) can be 

configured to work in Stand-Alone mode (Single Read Head) as well as 
Multidrop mode (Multiple Read Head.)  Most of the current bar code readers 
have been shipped to accommodate both single read head and multiple read 
head, with the addition of the Multidrop Series 5000 concentrator. This manual 
provides a description of the installation and operation of the Microscan 600 
series Bar Code Reader and Multidrop 5000 concentrator for single or multiple 
read head applications on the AGILENT 5DX Automatic Inspection System. 
Section One (1) discusses the configuration of the single read head BCR.  
Section Two (2) discusses the configuration of the multiple read head BCR and 
concentrator.

While many of the installation and operation parameters associated with this 
system are specific to the 5DX/BCR interface implementation, this manual has 
not been designed to serve as a theory of operation or software implementation 
specification. This manual has been designed to assist personnel in the 
installation and operation of the BCR subsystem for the AGILENT 5DX 
product line.  Agilent Technologies provides the bar code reader, cables, 
connectors, power supplies and other accessories. 

Please verify that the following items are included with the specific product as 
shown below.

MICROSCAN SERIES 600 (Agilent Technologies E7241A)

MICROSCAN 610-0002 BAR CODE READER

E7200-67977

RS232 ADP JUNCTION BOX

       

E7200-67978

BCR POWER SUPPLY

       

E7200-66409

BCR TO MASTER CPU INTERFACE CABLE 

E7200-61709

BCR TO ADP CABLE

       

1150-2046

MICROSCAN SERIES 5000 (Agilent Technologies E7242A)

MICROSCAN MUTIDROP CONCENTRATOR 

0960-0938

RS485 ADP JUNCTION BOX

0960-0939

MICROSCAN 610-0018 BCR HEAD

0960-1262

BCR TO ADP CABLE

1150-2046

T-CONN 9PIN 3-WAY

1252-7535

T-CONN TO CONCENTRATOR LAN CBL

8120-6956

ADP TO T-CONN CBL

8120-6957

CONCENTRATOR TO CPU CBL

             E7200-61709

BCR POWER SUPPLY

             E7200-66409

In addition to the bar code reader you will need the following to perform the 
installation and verify the operation.

Flat blade screwdriver

20 gage buss wire - 2”

Standard barcode labels

Summary of Contents for E7242A

Page 1: ...echnologies Automatic Barcode Reader 1 AGILENT TECHNOLOGIES AGILENT 5DX SERIES II 2L 3 AUTOMATIC BARCODE READER INSTALLATION AND OPERATION PROCEDURES FOR THE MICROSCAN IN LINE BARCODE READER SUBSYSTEM...

Page 2: ...rve as a theory of operation or software implementation specification This manual has been designed to assist personnel in the installation and operation of the BCR subsystem for the AGILENT 5DX produ...

Page 3: ...nnect the BCR components as shown in the diagram The AC power connection for the Power Supply is provide at the J Box mounted on the left rear corner of the AGILENT 5DX Main Cabinet on Series I throug...

Page 4: ...ad towards the standard bar code label at a distance of about 2 0 50mm and verify that the raster scans across the length of the bar code label Also check the power status green indicator light is lit...

Page 5: ...ensure that all cable connections are good If still failing try resetting the BCR head procedure on next page and test again If the BCR still cannot successfully scan any barcode you should replace th...

Page 6: ...ow From the 5DX User Interface window select SYSTEM Quit from 5DX The stand alone configuration file should already be set for a Microscan 600 series scanner However if it is necessary to change the b...

Page 7: ...oceed to the next step If an error mes sage is displayed re check the scnr cfg file for the correct setup 6 Verify BCR operation and alignment Position the scanner head towards the standard barcode la...

Page 8: ...he user can specify an m parameter to operate the executable in manual mode In this mode a read cycle can only be generated by pressing the SPACE BAR This will allow the user to slowly control the ali...

Page 9: ...nt Technologies Automatic Barcode Reader 9 Figure 9 ALIGNBCR Usage and Output for Manual Mode 8 Configure the Bar Code Reader from the Agilent 5DX User Interface Select System Sytem Access Configure 5...

Page 10: ...der 10 Figure 10 Screen shot of Result of Step 8 9 Use the arrow key and select In Line Bar Code Reader Figure 11 Screen shot of result of Step 9 10 Configure the menu to use the barcode reader and ma...

Page 11: ...hout the help of the customer The customer must provide the Serial Numbers for their boards panels to continue with the next step 11 Serial Numbers for loading CAD The customer must configure the Seri...

Page 12: ...he Microscan BCR scanner 610 0018 to work in either Stand Alone mode or Multidrop mode To configure in the multidrop mode refer to Figure 13 and follow the procedure below To configure in the standalo...

Page 13: ...1 on Series 3 on the 5DX to the first ADP 232 J4 connector Figure 15 Model 5DX Stand alone BCR Configuration 2 Power on the BCR ADP 232 The Scan Head should generate a continuous series of raster sca...

Page 14: ...t come on try these fixes Try scanning alternative barcode labels The first barcode sample may have been bad If still fails repeat Step 1 to ensure that all cable connections are good If still failing...

Page 15: ...d window From the 5DX User Interface window select System Sytem Access Quit 5DX The multidrop configuration file should be modified for the Microscan 600 series scanner and the Series 5000 concentrato...

Page 16: ...If no error message is generated then proceed to the next step If an error mes sage is displayed re check the scnr cfg file for the correct setup ADVICE Again the current scanner configuration will b...

Page 17: ...r pin 7 to pin 11 on the concentrator A series of beeps should be heard Disconnect one end of the jumper and then quickly reconnect the jumper a single long higher pitched beep should be heard This lo...

Page 18: ...rd barcode label Power on the ADP 232 and MS 5000 concentrator units if not already powered on From the Dos command prompt type alignbcr a The bar code reader will automatically start reading the bar...

Page 19: ...anners used There is a second way to run ALIGNBCR EXE The user can specify an m parameter to operate the executable in manual mode In this mode a read cycle can only be generated by pressing the SPACE...

Page 20: ...Automatic Barcode Reader 20 Figure 24 ALIGNBCR Usage and Output for Manual Mode 14 Configuration of the Bar Code Reader for the Agilent 5DX From the Agilent 5DX User Interface select System System Ac...

Page 21: ...igure 25 Screen shot of results of Step 14 15 Use the arrow key and select Use serial number to find panel name Use arrow keys and select In Line Bar Code Reader Figure 26 Screen shot of results of St...

Page 22: ...se is YES The number of bar code reader heads installed should be set to 2 or however many you are installing The read order of BCR heads should be set correctly Save changes Figure 28 Screen shot of...

Page 23: ...mbers for loading CAD The customer must configure the Serial Number option to match the bar code label numbers for the correct applications to be inspected Refer to the Agilent 5DX Online Reference Gu...

Reviews: