2000 Agilent Technologies
Automatic Barcode Reader
2
OVERVIEW
The Microscan BCR (
B
ar
C
ode
R
eader) scanner (FIS 610-0018) can be
configured to work in Stand-Alone mode (Single Read Head) as well as
Multidrop mode (Multiple Read Head.) Most of the current bar code readers
have been shipped to accommodate both single read head and multiple read
head, with the addition of the Multidrop Series 5000 concentrator. This manual
provides a description of the installation and operation of the Microscan 600
series Bar Code Reader and Multidrop 5000 concentrator for single or multiple
read head applications on the AGILENT 5DX Automatic Inspection System.
Section One (1) discusses the configuration of the single read head BCR.
Section Two (2) discusses the configuration of the multiple read head BCR and
concentrator.
While many of the installation and operation parameters associated with this
system are specific to the 5DX/BCR interface implementation, this manual has
not been designed to serve as a theory of operation or software implementation
specification. This manual has been designed to assist personnel in the
installation and operation of the BCR subsystem for the AGILENT 5DX
product line. Agilent Technologies provides the bar code reader, cables,
connectors, power supplies and other accessories.
Please verify that the following items are included with the specific product as
shown below.
MICROSCAN SERIES 600 (Agilent Technologies E7241A)
MICROSCAN 610-0002 BAR CODE READER
E7200-67977
RS232 ADP JUNCTION BOX
E7200-67978
BCR POWER SUPPLY
E7200-66409
BCR TO MASTER CPU INTERFACE CABLE
E7200-61709
BCR TO ADP CABLE
1150-2046
MICROSCAN SERIES 5000 (Agilent Technologies E7242A)
MICROSCAN MUTIDROP CONCENTRATOR
0960-0938
RS485 ADP JUNCTION BOX
0960-0939
MICROSCAN 610-0018 BCR HEAD
0960-1262
BCR TO ADP CABLE
1150-2046
T-CONN 9PIN 3-WAY
1252-7535
T-CONN TO CONCENTRATOR LAN CBL
8120-6956
ADP TO T-CONN CBL
8120-6957
CONCENTRATOR TO CPU CBL
E7200-61709
BCR POWER SUPPLY
E7200-66409
In addition to the bar code reader you will need the following to perform the
installation and verify the operation.
•
Flat blade screwdriver
•
20 gage buss wire - 2”
•
Standard barcode labels